Description
The serial trigger block is used to execute code when a data byte is recieved on a serial port.
Outputs
Output | Type | Description |
---|---|---|
Port 1 | FnCall | Function call when triggered. |
Parameters
Parameter | Type | Description |
---|---|---|
Serial Bus | String | The serial bus to trigger on. |
Always enabled | checkbox | When checked the trigger block will continue to operate even if the subsystem in which it is contained is disabled. |
Priority | Number | Positive number which determines the order in which multiple trigger blocks for the same mailbox are called. Triggers are executed from lowest to highest priority. |
Use Simulink Function | checkbox | Whether to use a Simulink Function or a triggered subsystem.
If a Simulink Function is used, it should be placed somewhere along the calling block's path to model root. |
Simulink Function Name | String | Name of the Simulink Function to call when this block is triggered. |
Create | button | Create a Simulink Function to use with the LIN Trigger block.
Must first provide a valid function name. |
Update | button | Update the listed Simulink Function's signature to 0 inputs & 0 outputs.
The Simulink Function listed in the box must already exist. |