Data-Loggers: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
 
(202 intermediate revisions by 13 users not shown)
Line 1: Line 1:
=Low-Cost CAN Based Data Logger=
{{DISPLAYTITLE:Data Loggers}}
{{Navigation}} '''Data Loggers'''


=== New Eagle CAN Data Logger ===
== Data Logging Introduction ==
Numerous data logging options are available based upon your application requirement.  New Eagle offers four ways to record and store data, usually collected via a CAN bus but also via discrete signals. 


The logger utilizes standard SD cards for data storage making it easy to retrieve data for applications including Event Data Logging (EDR). This device is capable of logging at rates of 1ms, making it an ideal choice for any CAN bus environment. Built in key switch detection and keep-alive circuitry ensure clean shutdowns and proper file closures.
=== Data Logging White Paper ===


[[file:NETM-CDL-001.jpg|right|300px]]
The white paper below details New Eagle's offerings in data management. It includes an application demo using both hardware and software tools, product comparisons, and advanced tutorials. Click below to view the document; you must be logged in to access it.


Features
{| class="wikitable" style="text-align: center;" cellpadding = "5"
*CAN data logging
**Easily log CAN bus data to an SD card
**Utilize configuration files to limit desired data or change CAN bus speed
**Data logging is limited only by the size of the SD card, right now 16GB cards are the largest supported.
*Real-time clock with battery backup providing date/time information for log files
*Firmware updates via SD Card
*Optional key switch detection
*Optional Configurable warning horn
*Status LED’s
**State of Health
**SD Card Presence and data logging
**Indicators for CAN Tx/Rx Traffic and Bus errors
**The log file is a text file format that lists all the CAN messages. This allows the user to import the data into excel or other programs.


{|class="wikitable" cellpadding = "5"  
!scope="col"| White Paper Download           


!scope="col"|Part Number
!scope="col"|Picture           
!scope="col"|'''[http://store.neweagle.net/ Visit our Webstore]'''
!scope="col"|Download
!scope="col"|More Information
|-
|-
|style = "width: 20%"|
|style = "height:180px; width:180px;"|
NETM-CDL-001
[[Image:DMPthumb.png|150px|link=http://www.neweagle.net/support/wiki/ProductDocumentation/Raptor/Displays/Data_Management_Platform_Whitepaper.pdf]]
|style = "width: 20%"|
<gallery>file:NETM-CDL-001.jpg</gallery>
|style = "width: 20%"|
[http://store.neweagle.net/products-by-category/telematics-and-data-loggers/new-eagle-canlogger-single-channel-can-data-logger-can-2-0b-up-to-8gb.html NETM-CDL-001]
|
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/Data_Logger_DataSheet.pdf New Eagle CANLogger Datasheet]'''
 
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/NE_Data_Logger_User_Manual_version_7.0.pdf New Eagle CANLogger User Manual]'''
|'''
|}
|}


=== New Eagle VeeCAN 320 Data Logger ===
== VeeCAN Data Loggers ==
The New Eagle data logger is built with Raptor on the VeeThree VeeCAN display platform.  The VeeCAN platform provides data logging options for reading CAN (J1939 or other protocol), RS485 (J1708), analog and discrete inputs.  The current configurations are found below.  If you need a different configuration, please [https://neweagle.net/contact/ call us].
=== VeeCAN 320 Data Logger ===
This logger utilizes a USB 2.0 stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500K, with logging at rates up to 1 ms to make this device an ideal choice for most CAN bus environments.


{|class="wikitable" cellpadding = "5"  
{| class="wikitable" style="text-align: center;" cellpadding = "5"


!scope="col"|Part Number
!scope="col"|Picture 
!scope="col"|Picture           
!scope="col"|Part Number         
!scope="col"|'''[http://store.neweagle.net/ Visit our Webstore]'''
!scope="col"|'''Webstore'''
!scope="col"|Download
!scope="col"|Downloads
!scope="col"|More Information
!scope="col"|More Information
|-
|-
|style = "width: 20%"|
|style = "height:180px; width:180px;"|
Coming Soon
[[File:NE_data_logger_v2.png|150px]]
|style = "width: 20%"|
<gallery>file:NETM-CDL-001.jpg</gallery>
|style = "width: 20%"|
[http://store.neweagle.net/products-by-category/telematics-and-data-loggers/new-eagle-canlogger-single-channel-can-data-logger-can-2-0b-up-to-8gb.html NETM-CDL-001]  
|
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/Data_Logger_DataSheet.pdf New Eagle CANLogger Datasheet]'''


'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/NE_Data_Logger_User_Manual_version_7.0.pdf New Eagle CANLogger User Manual]'''
|style = "height:180px; width:180px;"|
|'''
ASM-VC320DL-01
|}


|style = "height:180px; width:180px;"|
'''[https://store.neweagle.net/shop/products/data-loggers/raptor-veecan/raptor-veecan-320-data-logger/ Purchase]'''
|style = "height:180px; width:180px;"|
'''[[NE_VeeCAN320_Data_Logger#Downloads|Datasheet]]'''


'''[[NE_VeeCAN320_Data_Logger#Downloads|User Manual]]'''
|style = "height:180px; width:180px;"|
'''[[NE_VeeCAN320_Data_Logger|More Details]]'''
|}


====FAQs====
=== VeeCAN 320 Lite Data Logger ===
=====SD Cards=====
While sacrificing the standard VeeCAN 320 analog inputs, the VeeCAN 320 Lite is still a capable data logger designed with affordability in mind. The VeeCAN 320 Lite is usable with New Eagle's Raptor VeeCAN 320 data logging library which allows rapid implementation of data logging capability.
The data logger should be able to work with most SD cards. However, to help customers a selection of SD cards has been tested and verified to work. This list will be added to as more cards are tested. If you find a card that works well, let us know and we can test and add it to the list. The current approved SD cards are:


{| class="wikitable" style="text-align: center;" cellpadding = "5" 


*SanDisk SDHC – Class 4 – 4GB
!scope="col"|Picture 
*SanDisk Ultra HCI – Class 6 – 4GB
!scope="col"|Part Number         
*PNY HC – Class 10 – 8GB                     
!scope="col"|'''Webstore'''
*SanDisk Ultra HCII – Class 4 – 8GB
!scope="col"|Downloads
*SanDisk Extreme HD HCI – Class 10 – 8GB
!scope="col"|More Information
*SanDisk Extreme SDHC – Class 10 – 16GB
|-
|style = "height:180px; width:180px;"|
[[File:NE_data_logger_v2.png|150px]]


======SD Card Errors======
|style = "height:180px; width:180px;"|
Unfortunately, we cannot guarantee the approved SD cards will work  as needed because not all SD Cards are built equally. From our experience, the above SD Cards are the most reliable.
ASM-VC320DL-02


=====Log File Name=====
|style = "height:180px; width:180px;"|
The log file name needs to be LOGGER.MEC with all caps. Other names might load and work with the logger. However, the logger software might not pick up other names.
'''[https://store.neweagle.net/shop/products/data-loggers/raptor-veecan/veecan-320-lite-data-logger/ Purchase]'''
|style = "height:180px; width:180px;"|
'''[[NE_VeeCAN320_Data_Logger#Downloads|Datasheet]]'''


=====Auto Flush=====
'''[[NE_VeeCAN320_Data_Logger#Downloads|User Manual]]'''
A new auto flush feature has been added. This feature has the data logger back up the CAN information more often to the SD card. This means that data will be on the card if power is lost. If the option is not selected the SD card will back up, but not as often meaning data will be lost. The downside to the auto flush feature is that it lowers the performance of the data logger, so it cannot log as many messages.
|style = "height:180px; width:180px;"|
'''[[NE_VeeCAN320_Data_Logger|More Details]]'''
|}


Projects that seek to eliminate the key switch functionality should enable Auto Flush to ensure data capture.
==Data Logger with Real-Time Clock==


=====Extending User Action Button=====
This product is a CAN data logger for automotive applications, industrial, marine and autonomous transport systems.
The digital input is used to extend the user action button. When the input the unit will act as if the user action has been pressed. This allows you to use the action button when the data logger is installed elsewhere in the system. This feature is toggled by creating a switch that will pull the digital input pin (Pin 6) to ground.  


=====Voltage Spikes Above Operating Range=====
:'''Features include:'''
The unit is load dump protected up to 60v, though when the voltage rises above 33v the unit will shut down.  Therefore during transients like these the unit will be non-operational and self-recover when the input voltage returns to within specification.
:*Collects diagnostic data
:*Contains real-time clock
:*Robust and compact design


=====Circular Data Logging =====
{{LiBALdatalogger}}
A circular data logging system based upon memory size of the SD card, instead of key cycles, will be available September to October of 2013.


====How to Log Data====
Note: The standard unit comes with a 1 GB SD card.  It is capable of handling 32 GB cards of both commercial and industrial grade.


Logging data for the unit is very easy and straight forward, and involves setting up a short configuration file. This just takes a couple lines for the header and then a list of all the CAN messages you want to monitor. There are a couple of advanced fault options, but those are easy to use as well. You delete all files on the SD card and load the configuration file so it is the only file on the card. Next insert the SD card into the unit. The unit then has 8 LEDs and an action button. The datasheet tells you what each LED means, they include if CAN messaging is active on the bus, if the unit is recording, is there a fault, etc. The action button allows you to pause the data reading and to signal events to place a marker to be looked at.  
= Cellular-Based Data Logging=
The TCM is a standalone unit that can perform a multitude of functions from CAN data-aggregation and analytic processing to real-time vehicle monitoring through available cell networks. It can communicate desired parameter information to a web-based portal. Compatibility with the MotoHawk and Raptor development environments provides close integration with CAN bus systems.


When you are done pull the card out and plug it into the computer. There is a simple text file with all the CAN messages listed. This text file is formatted so that it can be imported into almost any CAN analyzing software.
:'''Features include:'''
:*CAN logging and remote diagnostics
:*Web portal interface
:*Remote flash
{|class="wikitable" style="text-align: center;" cellpadding = "5"
!scope="col"|Picture
!scope="col"|Part Number           
!scope="col"|'''Webstore'''
!scope="col"|Downloads
!scope="col"|More Information


There is also a free GUI that allows the user to more easily create the configuration file. That tool can be downloaded below.
|- style="vertical-align:middle;"
|style = "width:180px;" rowspan="6"|
[[Image:Telematics_c4max.jpg|150px]]
|style = "width:200px;"|
ASM-TCM-G01-USA<br>
ASM-TCM-G01-GLOBAL<br> <code> Data Logger Hardware </code>
|style = "width:180px;"|
'''[https://store.neweagle.net/product-category/products/data-loggers/cellular-based-telematics/ Purchase]'''
|style = "width:180px;"|
'''[[Raptor_Telematics_Downloads|Datasheet]]'''
|style = "width:180px;" rowspan="6"|


'''[[Telematics|More Details]]'''


====Configuration File Tool====
|- style="vertical-align:middle;"
|style = "width:180px;"|
ASM-TCM-P01-USA<br>
ASM-TCM-P01-GLOBAL<br> <code> Data Logger Hardware </code>
|style = "width:180px;"|
'''[https://store.neweagle.net/product-category/products/data-loggers/cellular-based-telematics/ Purchase]'''
|style = "width:180px;"|
'''[[Raptor_Telematics_Downloads|Datasheet]]'''


New Eagle offers translator software that translates the MEL raw CAN format on the SD card into engineering values using a DBC file.
|- style="vertical-align:middle;"
 
|style = "width:180px;"|
You can download a trial of the software below or purchase it immediately on the webstore.
ASM-NE-TMSVC-XX<br> <code> Service Plan </code>
 
|style = "width:180px;"|
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/NewEagle.DataLogger.ToolSuite.v1.0.0.2.zip New Eagle CANLogger Configuration File Program]'''
'''[https://store.neweagle.net/product-category/products/data-loggers/cellular-based-telematics/ Purchase]'''
 
|style = "width:180px;"|
====Software Update ====
Upon Request
The file to update the Datalogger to version 1.021 can be downloaded here, '''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/Firmware.bin Update File]'''.
|}
 
==== Datasheets ====
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/Data_Logger_DataSheet.pdf New Eagle CANLogger Datasheet]'''
 
'''[http://www.neweagle.net/support/wiki/docs/Datasheets/datalogger/NE_Data_Logger_User_Manual_version_7.0.pdf New Eagle CANLogger User Manual]'''
 
====Webstore====
'''[http://store.neweagle.net/products-by-manufacturer/new-eagle/telematics-and-data-loggers/new-eagle-canlogger-single-channel-can-data-logger-can-2-0b-up-to-8gb.html Webstore: New Eagle CANLogger]'''

Latest revision as of 16:38, 26 January 2023

New Eagle > Products Wiki > Data Loggers

Data Logging Introduction

Numerous data logging options are available based upon your application requirement. New Eagle offers four ways to record and store data, usually collected via a CAN bus but also via discrete signals.

Data Logging White Paper

The white paper below details New Eagle's offerings in data management. It includes an application demo using both hardware and software tools, product comparisons, and advanced tutorials. Click below to view the document; you must be logged in to access it.

White Paper Download

VeeCAN Data Loggers

The New Eagle data logger is built with Raptor on the VeeThree VeeCAN display platform. The VeeCAN platform provides data logging options for reading CAN (J1939 or other protocol), RS485 (J1708), analog and discrete inputs. The current configurations are found below. If you need a different configuration, please call us.

VeeCAN 320 Data Logger

This logger utilizes a USB 2.0 stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500K, with logging at rates up to 1 ms to make this device an ideal choice for most CAN bus environments.

Picture Part Number Webstore Downloads More Information

ASM-VC320DL-01

Purchase

Datasheet

User Manual

More Details

VeeCAN 320 Lite Data Logger

While sacrificing the standard VeeCAN 320 analog inputs, the VeeCAN 320 Lite is still a capable data logger designed with affordability in mind. The VeeCAN 320 Lite is usable with New Eagle's Raptor VeeCAN 320 data logging library which allows rapid implementation of data logging capability.

Picture Part Number Webstore Downloads More Information

ASM-VC320DL-02

Purchase

Datasheet

User Manual

More Details

Data Logger with Real-Time Clock

This product is a CAN data logger for automotive applications, industrial, marine and autonomous transport systems.

Features include:
  • Collects diagnostic data
  • Contains real-time clock
  • Robust and compact design
Picture Part Number Webstore Downloads More Information

LIB-CANDL-001
Data Logger Hardware

Purchase

Datasheet

User Manual

Software Manual

LIB-CANDL-HARN-001
Data Logger Harness

Purchase

Upon Request

LIB-CANDL-SW-001
Data Logger Software

Purchase

Upon Request

Note: The standard unit comes with a 1 GB SD card. It is capable of handling 32 GB cards of both commercial and industrial grade.

Cellular-Based Data Logging

The TCM is a standalone unit that can perform a multitude of functions from CAN data-aggregation and analytic processing to real-time vehicle monitoring through available cell networks. It can communicate desired parameter information to a web-based portal. Compatibility with the MotoHawk and Raptor development environments provides close integration with CAN bus systems.

Features include:
  • CAN logging and remote diagnostics
  • Web portal interface
  • Remote flash
Picture Part Number Webstore Downloads More Information

ASM-TCM-G01-USA
ASM-TCM-G01-GLOBAL
Data Logger Hardware

Purchase

Datasheet

More Details

ASM-TCM-P01-USA
ASM-TCM-P01-GLOBAL
Data Logger Hardware

Purchase

Datasheet

ASM-NE-TMSVC-XX
Service Plan

Purchase

Upon Request