== Description ==
== Description ==
<p>The serial trigger block is used to execute code when a data byte is recieved on a serial port.</p>
<p>The serial trigger block is used to execute code when a data byte is recieved on a serial port.</p>
== Inputs ==
{| class="wikitable" style="width:75%;"
|-
! scope="col" style="width: 15%;"|Input
! scope="col" style="width: 15%;"|Type
! scope="col" style="width: 70%;"|Description
|}


== Outputs ==
== Outputs ==
Line 23: Line 15:
! scope="col" style="width: 70%;"|Description
! scope="col" style="width: 70%;"|Description
|-
|-
!  
! Port 1
| FnCall
| FnCall
| Function call when triggered.
| Function call when triggered.
Line 39: Line 31:
| The serial bus to trigger on.
| The serial bus to trigger on.
|-
|-
! Always enabled even when containing system is disabled.
! Always enabled
|  
| checkbox
| When checked the trigger block will continue to operate even if the subsystem in which it is contained is disabled.
| When checked the trigger block will continue to operate even if the subsystem in which it is contained is disabled.
|-
|-
Line 46: Line 38:
| Number
| Number
| Positive number which determines the order in which multiple trigger blocks for the same mailbox are called. Triggers are executed from lowest to highest priority.  
| Positive number which determines the order in which multiple trigger blocks for the same mailbox are called. Triggers are executed from lowest to highest priority.  
|-
! Use Simulink Function
| checkbox
| Whether to use a Simulink Function or a triggered subsystem.
If a Simulink Function is used, it should be placed somewhere along the calling block's path to model root.
|-
! Simulink Function Name
| String
| Name of the Simulink Function to call when this block is triggered.
|-
! Create
| button
| Create a Simulink Function to use with the LIN Trigger block.
Must first provide a valid function name.
|-
! Update
| button
| Update the listed Simulink Function's signature to 0 inputs & 0 outputs.
The Simulink Function listed in the box must already exist.
|}
|}

Latest revision as of 14:35, 14 September 2023

Return to the main Raptor page

Return to Serial page

Raptor™ Serial Trigger

Description

The serial trigger block is used to execute code when a data byte is recieved on a serial port.

Outputs

Output Type Description
Port 1 FnCall Function call when triggered.

Parameters

Parameter Type Description
Serial Bus String The serial bus to trigger on.
Always enabled checkbox When checked the trigger block will continue to operate even if the subsystem in which it is contained is disabled.
Priority Number Positive number which determines the order in which multiple trigger blocks for the same mailbox are called. Triggers are executed from lowest to highest priority.
Use Simulink Function checkbox Whether to use a Simulink Function or a triggered subsystem.

If a Simulink Function is used, it should be placed somewhere along the calling block's path to model root.

Simulink Function Name String Name of the Simulink Function to call when this block is triggered.
Create button Create a Simulink Function to use with the LIN Trigger block.

Must first provide a valid function name.

Update button Update the listed Simulink Function's signature to 0 inputs & 0 outputs.

The Simulink Function listed in the box must already exist.