Raptor:PGN Trigger: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(One intermediate revision by the same user not shown)
Line 8: Line 8:
<p>The PGN trigger block is used to trigger a message to be sent when it is requested. This block will execute the function connected to it's output when a Request message is received for the specified PGN and the PGN is enabled. If the controller has not successfully acquired an address this output will not be executed. This block includes a Raptor Adjustment and Measurement to show the enable state of the PGN and allow it to be disabled. Only one PGN trigger block can be included in the model for any given PGN and J1939 bus.</p>
<p>The PGN trigger block is used to trigger a message to be sent when it is requested. This block will execute the function connected to it's output when a Request message is received for the specified PGN and the PGN is enabled. If the controller has not successfully acquired an address this output will not be executed. This block includes a Raptor Adjustment and Measurement to show the enable state of the PGN and allow it to be disabled. Only one PGN trigger block can be included in the model for any given PGN and J1939 bus.</p>


== Inputs ==
<p>Note: a PGN trigger block and a PGN enable block cannot be configured with the same PGN and the same J1939 bus in the same model, due to conflicting calibration names. If this functionality is desired, use the PGN Trigger - No Cal block, which does not have this limitation but removes the ability to control the block in Raptor-Cal.</p>
{| class="wikitable" style="width:75%;"
|-
! scope="col" style="width: 15%;"|Input
! scope="col" style="width: 15%;"|Type
! scope="col" style="width: 70%;"|Description
|}


== Outputs ==
== Outputs ==
Line 23: Line 17:
! scope="col" style="width: 70%;"|Description
! scope="col" style="width: 70%;"|Description
|-
|-
!  
! Port 1
| function call
| function call
| Trigger indicating reception of PGN.
| Trigger indicating reception of PGN.

Latest revision as of 13:14, 14 September 2023

Return to the main Raptor page

Return to Transport Protocol page

Raptor™ PGN Trigger

Description

The PGN trigger block is used to trigger a message to be sent when it is requested. This block will execute the function connected to it's output when a Request message is received for the specified PGN and the PGN is enabled. If the controller has not successfully acquired an address this output will not be executed. This block includes a Raptor Adjustment and Measurement to show the enable state of the PGN and allow it to be disabled. Only one PGN trigger block can be included in the model for any given PGN and J1939 bus.

Note: a PGN trigger block and a PGN enable block cannot be configured with the same PGN and the same J1939 bus in the same model, due to conflicting calibration names. If this functionality is desired, use the PGN Trigger - No Cal block, which does not have this limitation but removes the ability to control the block in Raptor-Cal.

Outputs

Output Type Description
Port 1 function call Trigger indicating reception of PGN.

Parameters

Parameter Type Description
J1939 Bus Name String This is the name of the J1939 bus.
PGN uint32 The PGN to receive.