Data-Loggers: Difference between revisions
Line 110: | Line 110: | ||
==New Eagle CDL Translation Software== | ==New Eagle CDL Translation Software== | ||
New Eagle offers translator software that translates the MEL raw CAN format on USB stick/SD card into engineering values using a DBC file. | New Eagle offers translator software for both the CAN data logger and the VeeCAN 320 data logger that translates the MEL raw CAN format on USB stick/SD card into engineering values using a DBC file. | ||
You can purchase it immediately on our [http://store.neweagle.net/catalogsearch/result/?q=NETM-CDL-SW-001 web store] | |||
You can purchase it immediately on our [http://store.neweagle.net/catalogsearch/result/?q=NETM-CDL-SW-001 web store] or request a trial from [sales@neweagle.net sales]. | |||
''''Part Number'''' | ''''Part Number'''' |
Revision as of 13:32, 17 December 2013
Introduction
New Eagle offers two embedded data logger solutions which both provide the capability for event data recording, and vehicle / system monitoring at a reasonable cost.
New Eagle Low-Cost CAN Data Logger
The logger utilizes standard SD cards for data storage making it easy to retrieve data for applications including Event Data Logging (EDR). This device is capable of logging at rates of 1ms, making it an ideal choice for any CAN bus environment. Built in key switch detection and keep-alive circuitry ensure clean shutdowns and proper file closures.
Features
- CAN data logging
- Easily log CAN bus data to an SD card
- Utilize configuration files to limit desired data or change CAN bus speed
- Can log in a circular buffer method to keep most recent data when card is full, to function as a Event Data Recorder (Black Box).
- Data logging is limited only by the size of the SD card, right now 16GB cards are the largest supported.
- Real-time clock with battery backup providing date/time information for log files
- Firmware updates via SD Card
- Optional key switch detection
- Optional Configurable warning horn
- Status LED’s
- State of Health
- SD Card Presence and data logging
- Indicators for CAN Tx/Rx Traffic and Bus errors
- The log file is a text file format that lists all the CAN messages. This allows the user to import the data into excel or other programs.
Part Number | Picture | Visit our Webstore | Download | More Information |
---|---|---|---|---|
NETM-CDL-001 |
|
New Eagle Data Logger |
New Eagle VeeCAN320 Data Logger
This logger utilizes a USB stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500k, with logging at rates up to 1ms to make this device is an ideal choice for most CAN bus environments. While the unit can function without user intervention, an interface button is provided to allow for multiple logging sessions. This data logging device can survive in the harshest environments due to its robust components.
Features
- CAN data logging
- Logging CAN bus data to a USB stick
- Provides 2 CAN channels for data logging
- 250 KBaud CAN1 Bus, 500 KBaud CAN2 Bus
- Data Logging is limited only by the size of USB drive
- Logging is started automatically when USB stick is plugged in, also starts on power-up if stick is in place
- Logging session is controlled via a button
- Capable of logging at rate of 1ms
- 320*240 pixel color display for real-time displaying logging status
- 10V-32V DC Powered
- Save data as text files, this allows the users to import data into excel or matlab.
- -20 - +70 degrees C operating temperature
- RS232 interface (available for custom logging applications)
Part Number | Picture | Visit our Webstore | Download | More Information |
---|---|---|---|---|
ASM-RAP-VCDL-001 |
|
Coming Soon |
NE VeeCAN320 Data Logger |
Choosing Between the VeeCAN320 Data Logger and the Low-cost Data Logger
Built on a more capable hardware platform, the VeeCAN320 Data Logger has additional features and may provide better performance compared to the Low-cost Data Logger in your application. Also, for the VEECAN320 logger, customization is available to more closely tailor the logging application to your needs.
Low-Cost CAN Data Logger | VeeCAN320 Data Logger |
---|---|
SD card storage, 16GB cards are the largest size supported |
USB stick storage, no size limitation (although 16GB recommended) |
Utilize key switch to control the logging session, only one logging session allowed in a key cycle | Logger can function without user intervention, an interface button is provided to allow for multiple logging sessions in one key cycle |
Only one CAN channel is available | Two CAN channels are available, allow users to log data on both CAN channels at the same time |
CAN based collection only | Standard collection is from CAN, but customization is available to utilize the discrete I/O on the VeeCAN 320 display |
Logging status is indicated by LEDs | Provide big colorful display for real-time showing logging status |
New Eagle CDL Translation Software
New Eagle offers translator software for both the CAN data logger and the VeeCAN 320 data logger that translates the MEL raw CAN format on USB stick/SD card into engineering values using a DBC file.
You can purchase it immediately on our web store or request a trial from [sales@neweagle.net sales].
'Part Number' NETM-CDL-SW-001
'How To Use It'
This software is easily to use, open it, use "Browse" to choose DBC file and data file (.MEL), respectively, then click "Convert". After a few seconds, the MEL raw data will be translated into engineering values.
'Other Option to CDL'
The mel raw data file is a text file, which is formatted so that it can be easily imported into Matlab or Excel, the user needs to create scripts to translate the raw data (hex value) into engineering values.