Description
This block implements PGN 64949 Previously Active Emission Related Faults (DM23). This block works with the Raptor OBD Fault Manager and sends all the faults in the previously active state which are defined as emissions-related. Use the raptor_j1939_spn_write block with SPNs 1213, 623, 624, 987, 3038, 3039, 3040 to set the lamp statuses.
Inputs
Input | Type | Description |
---|
Outputs
Output | Type | Description |
---|
Parameters
Parameter | Type | Description |
---|---|---|
J1939 Bus Name | String | This is the name of the J1939 bus. |