Line 44: Line 44:


     A. IP6K9K
     A. IP6K9K
Q: There is approximately 13 seconds delay for the controller to go to sleep once WAKE_INPUT1 pin is low. Is this adjustable?
    A: Yes, the Bosch 196-pin module has a timer (SyC_tiPostDrvMax_C) that needs to be serviced by the keyswitch (WAKE_INPUT1).
        One way to change SyC_tiPostDrvMax_C:
        Using a 196-pin raptor module in Raptor-Cal, there is a calibration called “SyC_tiPostDrvMax_C” located under System/Platform:
       
        Transfer Calibrations and select .rpg to .rpg. Change the calibration by using Set Value. Then Save to (.rpg).


==Other Modules==
==Other Modules==
'''[[Controllers | Back to: Controllers]]'''
'''[[Controllers | Back to: Controllers]]'''

Revision as of 13:16, 25 May 2018

GCM-1793-196-15031 (GCM196)

The GCM196 is a general purpose control module. The module has 3 CAN buses, making it suitable for system supervisory applications in which communication with many system components is necessary. The extensive amount of inputs and outputs, memory and processing capability make this module suitable for a wide variety of general purpose applications. The dual processors make this module suitable for safety critical applications where redundant processing is required.

The Infineon Tricore TC1793 CPU inside the GCM196 is a highly capable compute platform, capable of handling highly complex control algorithms and processor load.

The GCM196 is part of a family of rugged, automotive-grade production controllers that use a software development process based on MATLAB/Simulink, known as Raptor-Dev. Raptor-Dev significantly speeds up algorithm development by using automatic code generation. In addition, developers can quickly test application software on their PCs with a built-in onscreen PC simulation. See the next page for more details.

Data Sheets

  • GCM-1793-196-1503
Datasheet
  • ECM-1793-196-1503
Datasheet

Pins and Crimping

Due to the high number of pins on the GCM196, the pins need to be crimped in a very specific fashion.
To reduce problems while attempting to pin the GCM196 please refer to the following pictures:

Crimping Tool

Click Here to purchase your crimper today.

Please note, TOOL-CON-010-00 is for prototyping on the ECM/GCM196 and is not recommended for production harness manufacturing.

Compiler

Hightec-DP-TC - Hightec Tricore Development Platform Compiler (Node-Lock)
Hightec TriCore Development Platform (Node locked) includes C/C++ Compiler, Assembler, Linker/Locator; PCP-C Compiler, Eclipse IDE, Standard libraries.

Click Here to purchase your compiler today.


Q&A

Q: Does New Eagle have a specification for the boot up time for the GCM196? Ie. Time required to execute the first foreground loop from application of 12V on wake up pin

    A: Yes, the foreground loops approximately 190ms after the wake-pin is enabled.

Q: What is the weight of the 196?

    A.  2.2 Lbs or 1000 grams

Q: What is the Environment Rating of the 196?

    A. IP6K9K

Q: There is approximately 13 seconds delay for the controller to go to sleep once WAKE_INPUT1 pin is low. Is this adjustable?

    A: Yes, the Bosch 196-pin module has a timer (SyC_tiPostDrvMax_C) that needs to be serviced by the keyswitch (WAKE_INPUT1).
       One way to change SyC_tiPostDrvMax_C:
       Using a 196-pin raptor module in Raptor-Cal, there is a calibration called “SyC_tiPostDrvMax_C” located under System/Platform:
       
       Transfer Calibrations and select .rpg to .rpg. Change the calibration by using Set Value. Then Save to (.rpg).

Other Modules

Back to: Controllers