RCM-5743R-080: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
:'''[https://neweagle.net/support/wiki/ProductDocumentation/Raptor/Controllers/RCM-5743R-080-2106_DataSheet.pdf RCM80-2106 Datasheet]'''
:'''[https://neweagle.net/support/wiki/ProductDocumentation/Raptor/Controllers/RCM-5743R-080-2106_DataSheet.pdf RCM80-2106 Datasheet]'''
*'''RCM-5743R-080-2203'''
*'''RCM-5743R-080-2203'''
:'''[https://neweagle.net/support/wiki/ProductDocumentation/Raptor/Controllers/RCM-5743R-080-2111_DataSheet.pdf RCM80-2203 Datasheet]'''
:'''[https://neweagle.net/support/wiki/ProductDocumentation/Raptor/Controllers/RCM-5743R-080-2203_DataSheet.pdf RCM80-2203 Datasheet]'''


==Compiler ==
==Compiler ==

Revision as of 20:43, 15 February 2022

RCM80

The RCM80 is a Raptor general-purpose control module with 4 CAN buses, 1 LIN Master/Slave, and configurable discrete inputs and outputs including analog inputs, frequency inputs, a wake input, high and low-side driver outputs, and temperature sensor inputs.

The RCM80 is one of the Raptor™ rugged production controllers that use a software development process based upon MATLAB/Simulink and Raptor-Dev which significantly speeds up algorithm development by using automatic integration and code generation. In addition, developers can quickly test application software using simulation and automated testing. See the next page for more details.

Data Sheets

  • RCM-5743R-080-2005
RCM80-2005 Datasheet
  • RCM-5743R-080-2106
RCM80-2106 Datasheet
  • RCM-5743R-080-2203
RCM80-2203 Datasheet

Compiler

S32 Design Studio for Power Architecture v2.1
Please reference the following Document to download and install the compiler from NXP's website.

RCM80 Compiler Installation Guide

CAD Model

To obtain the CAD file for the RCM80 Enclosure, please submit a ticket on our Support Portal requesting access.

Frequently Asked Questions (FAQ)

Q: What is not supported with the RCM80-2005

    A: The RCM80-2005 is an A-Sample unit that does NOT support frequency_in measurement capability on DG 9. 
       It also does NOT contain Flyback Diodes on the PWM outputs. 
       Furthermore LIN1 is ONLY capable of LIN Master (hardware issue).

Q: What is new with the RCM80-2106

    A: The RCM80-2106 is a B-Sample unit that resolves issue found in the RCM80-2005 A samples. 
       It fully implements Frequency measurement capabilities on DG9. 
       Additionally, Flyback Diodes have been implemented on all HSOs and LSOs. 
       Lastly LIN1 is capable of LIN Master AND LIN Slave (Software Selectable). 

Q: What is new with the RCM80-2203

    A: The RCM80-2203 is a C-Sample unit. There is a Substantial change in the power architecture (External Main Power Relay REQUIRED for driving external loads.) 
       There have been adjustments in QUANTITY of IO and changes to the PIN-OUT.
       Reference Datasheet for specific changes to ensure unit continues to meet IO needs.

Webstore

To purchase, visit our webstore.
Buy Now

Other Modules

Back to: Controllers