Raptor-Dev-Triggers: Difference between revisions
No edit summary |
No edit summary |
||
Line 29: | Line 29: | ||
| <p>This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help.</p> | | <p>This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help.</p> | ||
| [[file:RaptorTimedTriggerConfiguration.jpg|frameless|border|Timed Trigger Configuration block|center]] | | [[file:RaptorTimedTriggerConfiguration.jpg|frameless|border|Timed Trigger Configuration block|center]] | ||
|} | |- | ||
! <h5>[[Raptor:App Trigger|App Trigger]]</h5> | |||
| <p>This block triggers a subsystem upon activation of an application event.</p> | |||
| [[file:RaptorAppTrigger.JPG|frameless|border|App Trigger block|center]] | |||
|- | |||
! <h5>[[Raptor:Shut-down|Shut-down]]</h5> | |||
| <p>Triggers a write of all non-volatile data to EEPROM within the ECU.</p> | |||
| [[file:RaptorShutdown.JPG|frameless|border|Shut-down block|center]] | |||
| | |||
} |
Revision as of 19:44, 6 May 2014
Return to the main Raptor page
Return to the Essential Libraries page
The blocks in this subsystem are define and configure application triggers.
Blocks
Block | Description | Appearance | |
---|---|---|---|
Raptor dT |
This block outputs the delta time since the last time it was executed. |
||
Time |
This block outputs the time since the model began execution. |
||
Timed Trigger |
This block is used to trigger periodic functions in the program. The function call output is triggered at the rate specified in by the parameter. Raptor timed triggers support stepping with the application monitor to aid in debugging. |
||
Timed Trigger Configuration |
This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help. |
||
App Trigger |
This block triggers a subsystem upon activation of an application event. |
||
Shut-down |
Triggers a write of all non-volatile data to EEPROM within the ECU. |
} |