Raptor-Dev-Triggers: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 29: Line 29:
| <p>This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help.</p>
| <p>This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help.</p>
| [[file:RaptorTimedTriggerConfiguration.jpg|frameless|border|Timed Trigger Configuration block|center]]
| [[file:RaptorTimedTriggerConfiguration.jpg|frameless|border|Timed Trigger Configuration block|center]]
|}
|-
! <h5>[[Raptor:App Trigger|App Trigger]]</h5>
| <p>This block triggers a subsystem upon activation of an application event.</p>
| [[file:RaptorAppTrigger.JPG|frameless|border|App Trigger block|center]]
|-
! <h5>[[Raptor:Shut-down|Shut-down]]</h5>
| <p>Triggers a write of all non-volatile data to EEPROM within the ECU.</p>
| [[file:RaptorShutdown.JPG|frameless|border|Shut-down block|center]]
|
}

Revision as of 19:44, 6 May 2014

Return to the main Raptor page

Return to the Essential Libraries page

Raptor™ Triggers

The blocks in this subsystem are define and configure application triggers.

Blocks

Block Description Appearance
Raptor dT

This block outputs the delta time since the last time it was executed.

Raptor dT block
Raptor dT block
Time

This block outputs the time since the model began execution.

Time block
Time block
Timed Trigger

This block is used to trigger periodic functions in the program. The function call output is triggered at the rate specified in by the parameter. Raptor timed triggers support stepping with the application monitor to aid in debugging.

Timed Trigger block
Timed Trigger block
Timed Trigger Configuration

This block allows certain base timed trigger periods to be modified. This block is target dependant. Place this block in a model with a target definition block and then enter the block's help again for more specific help.

Timed Trigger Configuration block
Timed Trigger Configuration block
App Trigger

This block triggers a subsystem upon activation of an application event.

App Trigger block
App Trigger block
Shut-down

Triggers a write of all non-volatile data to EEPROM within the ECU.

Shut-down block
Shut-down block

}