==Introduction== | ==Introduction== | ||
New Eagle offers | New Eagle offers 3 embedded data logger solutions which both provide the capability for event data recording, and vehicle / system monitoring at a reasonable cost. | ||
== | == VeeCAN Data Loggers == | ||
=== VeeCAN 320 Datalogger === | |||
This logger utilizes a USB 2.0 stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500k, with logging at rates up to 1ms to make this device is an ideal choice for most CAN bus environments. While the unit can function without user intervention, an interface button is provided to allow for multiple logging sessions. This data logging device can survive in the harshest environments due to its robust components. | This logger utilizes a USB 2.0 stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500k, with logging at rates up to 1ms to make this device is an ideal choice for most CAN bus environments. While the unit can function without user intervention, an interface button is provided to allow for multiple logging sessions. This data logging device can survive in the harshest environments due to its robust components. | ||
[[File:OWL.jpg|right|400px]] | [[File:OWL.jpg|right|400px]] | ||
=== Features === | ==== Features ==== | ||
*CAN data logging | *CAN data logging | ||
**Logging CAN bus data to a USB stick | **Logging CAN bus data to a USB stick | ||
Line 50: | Line 51: | ||
'''[http://www.neweagle.net/support/wiki/index.php?title=NE_VeeCAN320_Data_Logger VeeCAN320 Data Logger]''' | '''[http://www.neweagle.net/support/wiki/index.php?title=NE_VeeCAN320_Data_Logger VeeCAN320 Data Logger]''' | ||
|} | |} | ||
=== VeeCAN 320 Light Datalogger === | |||
While Sacrificing the standard VeeCAN 320 analog inputs, the VeeCAN 320 light is still a capable Datalogger designed with affordability in mind. The VeeCAN 320 Light still maintains the standard VeeCAN 320's Durable design and useful user interface button as well as its CAN channel and USB port. Moreover, The VeeCAN 320 light is usable with New Eagle's Raptor VeeCAN 320 datalogging library which allows rapid implementation of datlogging capability. | |||
{|class="wikitable" cellpadding = "5" | |||
!scope="col"|Part Number | |||
!scope="col"|Picture | |||
!scope="col"|'''[http://store.neweagle.net/ Visit our Webstore]''' | |||
!scope="col"|Download | |||
!scope="col"|More Information | |||
|- | |||
|style = "height:180px; width:180px;"| | |||
ASM-VC320DL-02 | |||
|style = "height:180px; width:180px;"| | |||
<gallery>File:NE_data_logger_v2.png</gallery> | |||
|style = "height:180px; width:180px;"| | |||
[http://store.neweagle.net/new-eagle-veecan-320-lite-data-logger.html ASM-VC320DL-02] | |||
|style = "height:180px; width:180px;"| | |||
'''Coming Soon''' | |||
|style = "height:180px; width:180px;"| | |||
'''Coming Soon''' | |||
|} | |||
== Raptor VeeCAN 320 Datalogging Library == | == Raptor VeeCAN 320 Datalogging Library == | ||
The Raptor VeeCAN 320 Datalogging Library is ideal for implementing | The Raptor VeeCAN 320 Datalogging Library is ideal for implementing a VeeCAN Data Logger using Raptor software. Raptor users will appreciate the ease of creating a utility that logs CAN messages from the Raptor controller. | ||
{|class="wikitable" cellpadding = "5" | {|class="wikitable" cellpadding = "5" | ||
Revision as of 18:30, 24 February 2015
IntroductionNew Eagle offers 3 embedded data logger solutions which both provide the capability for event data recording, and vehicle / system monitoring at a reasonable cost. VeeCAN Data LoggersVeeCAN 320 DataloggerThis logger utilizes a USB 2.0 stick for data storage and effortless data retrieval. Two CAN channels are provided, preconfigured to 250K and 500k, with logging at rates up to 1ms to make this device is an ideal choice for most CAN bus environments. While the unit can function without user intervention, an interface button is provided to allow for multiple logging sessions. This data logging device can survive in the harshest environments due to its robust components. ![]() Features
VeeCAN 320 Light DataloggerWhile Sacrificing the standard VeeCAN 320 analog inputs, the VeeCAN 320 light is still a capable Datalogger designed with affordability in mind. The VeeCAN 320 Light still maintains the standard VeeCAN 320's Durable design and useful user interface button as well as its CAN channel and USB port. Moreover, The VeeCAN 320 light is usable with New Eagle's Raptor VeeCAN 320 datalogging library which allows rapid implementation of datlogging capability.
Raptor VeeCAN 320 Datalogging LibraryThe Raptor VeeCAN 320 Datalogging Library is ideal for implementing a VeeCAN Data Logger using Raptor software. Raptor users will appreciate the ease of creating a utility that logs CAN messages from the Raptor controller.
Low-Cost CAN Data LoggerThe logger utilizes standard SD cards for data storage making it easy to retrieve data for applications including Event Data Logging (EDR). This device is capable of logging at rates of 1ms, making it an ideal choice for any CAN bus environment. Built in key switch detection and keep-alive circuitry ensure clean shutdowns and proper file closures. ![]() Features
Choosing Between the VeeCAN320 Data Logger and the Low-Cost Data LoggerBuilt on a more capable hardware platform, the VeeCAN320 Data Logger has additional features and may provide better performance compared to the Low-cost Data Logger in your application. Also, for the VEECAN320 logger, customization is available to more closely tailor the logging application to your needs.
Data Logger Translation SoftwareNew Eagle offers translator software for both the CAN data logger and the VeeCAN 320 data logger that translates the MEL raw CAN format on USB stick/SD card into engineering values using a DBC file. Also, this translator software can translate CANKIng format data. You can purchase it immediately on our web store or request a trial from contact us.
How To Use It:
This software is easily to use, open it, use "Browse" to choose DBC file and data file (.MEL or .txt), respectively, then click "Convert". After a few seconds, the MEL raw data will be translated into engineering values.
|