RCM-5743R-080: Difference between revisions
Line 24: | Line 24: | ||
The most up to date ECU information is found on the [https://neweagle.freshdesk.com/a/solutions '''support portal'''] | The most up to date ECU information is found on the [https://neweagle.freshdesk.com/a/solutions '''support portal'''] | ||
Q: What is not supported with the RCM80-2005 | Q: What is not supported with the RCM80-2005 | ||
Revision as of 17:42, 5 December 2022
RCM80
The RCM80 is a Raptor general-purpose control module with 4 CAN buses, 1 LIN Master/Slave, and configurable discrete inputs and outputs including analog inputs, frequency inputs, a wake input, high and low-side driver outputs, and temperature sensor inputs.
The RCM80 is one of the Raptor™ rugged production controllers that use a software development process based upon MATLAB/Simulink and Raptor-Dev which significantly speeds up algorithm development by using automatic integration and code generation. In addition, developers can quickly test application software using simulation and automated testing. See the next page for more details.
Data Sheets
- RCM-5743R-080-2106 Pre-Production
- RCM-5743R-080-2203 Production
Compiler
S32 Design Studio for Power Architecture v2.1
Please reference the following Document to download and install the free compiler from NXP's website.
RCM80 Compiler Installation Guide
CAD Model
To obtain the CAD file for the RCM80 Enclosure, please submit a ticket on our Support Portal requesting access.
Frequently Asked Questions (FAQ)
The most up to date ECU information is found on the support portal
Q: What is not supported with the RCM80-2005
A: The RCM80-2005 is an A-Sample unit that does NOT support frequency_in measurement capability on DG 9. It also does NOT contain Flyback Diodes on the PWM outputs. Furthermore LIN1 is ONLY capable of LIN Master (hardware issue).
Q: What is new with the RCM80-2106
A: The RCM80-2106 is a B-Sample unit that resolves issue found in the RCM80-2005 A samples. It fully implements Frequency measurement capabilities on DG9. Additionally, Flyback Diodes have been implemented on all HSOs and LSOs. Lastly LIN1 is capable of LIN Master AND LIN Slave (Software Selectable).
Q: What is new with the RCM80-2203
A: The RCM80-2203 is a C-Sample unit. There is a Substantial change in the power architecture (External Main Power Relay REQUIRED for driving external loads.) There have been adjustments in QUANTITY of IO and changes to the PIN-OUT. Reference Datasheet for specific changes to ensure unit continues to meet IO needs.
End-Of-Life Modules
- RCM-5743R-080-2005
Webstore
To purchase, visit our webstore.