This block defines a fault and set its status. The Raptor Fault Manager block must exist in the model to use this block.
Inputs
Input
Type
Description
Outputs
Output
Type
Description
Parameters
Parameter
Type
Description
Fault Name
String
Defines the name of the fault. Must be a valid C identifier.
Persistent
Defines if the fault is persistent (state is remembered through a power cycle).
Sticky
Defines if the fault is sticky (must be cleared to stop being active).
X Count
Number
Input status must be true for this many count out of the last Y to set the fault as Active.
Y Count
Number
Number of executions to track input status over.
Calibratable X/Y Count
Allows the X and Y count limits to be changed in the calibtation tool.
Access Level
Sets the access level of X/Y limits in the calibration tool.
Function
String
Sets the location where the X/Y limit appears in the calibration tool. Use raptor_xcp_function(gcb) to create a function based on the variables location in the model.