Description

This block shows the status of the selected output. On modules which support output diagnostics this block can show if an output is shorted or shutdown do to over current.

The following status codes have been defined, however not all status codes may be supported be each module or output.

Value Description
0 No Fault
1 Output On
2 Short Circuit Detected
3 Over Current Detected
4 Open Load Detected
5 Back Driven Detected

e.g. LSD grounded, HSD shorted to battery

6 No Supply Voltage
7 Possible Short Circuit Detected
8 Over Voltage
9 Under Voltage

Inputs

Input Type Description

Outputs

Output Type Description
Faulted boolean Shows the fault status of the selected resource. Ok = 0, Faulted = 1
Status Code uint8 Shows more detailed fault status information on the output.

Parameters

Parameter Type Description
Hardware Resource Specifies which input from the hardware is being read.

Supported Versions