Description
This block reads the value of a frequency input. Some modules also support duty cycle measurement through this input.
Inputs
Outputs
Output
|
Type
|
Description
|
Frequency Input
|
uint32
|
The frequency of the selected input in 0.01Hz. For example, a raw value of 1000 = 10Hz
|
Duty Cycle
|
uint16
|
The duty cycle of the selected input in 0.01%. For example, a raw value of 5000 = 50% duty cycle.
|
Parameters
Parameter
|
Type
|
Description
|
Hardware Resource
|
|
Specifies which input from the hardware is being read.
|
Pull Up/Down
|
|
Specifies pull up/down resistor for input on modules which support this function.
|
Duty Cycle Measurement
|
|
Enables duty cycle measurement on inputs and modules which support this function.
|