Raptor:Fault Definition
Jump to navigation
Jump to search
Return to the main Raptor page
Description
This block defines a fault and set its status. The Raptor Fault Manager block must exist in the model to use this block. This block has different input, output and parameters depending on the type of fault manager selected.
Parameters
Parameter | Type | Description |
---|---|---|
Fault Name | String | Defines the name of the fault. Must be a valid C identifier. |
Persistent | Defines if the fault is persistent (state is remembered through a power cycle). | |
Sticky | Defines if the fault is sticky (must be cleared to stop being active). | |
X Count | Number | Input status must be true for this many count out of the last Y to set the fault as Active. |
Y Count | Number | Number of executions to track input status over. |
Calibratable X/Y Count | Allows the X and Y count limits to be changed in the calibtation tool. | |
Access Level | Sets the access level of X/Y limits in the calibration tool. | |
Function | String | Sets the location where the X/Y limit appears in the calibration tool. Use raptor_xcp_function(gcb) to create a function based on the variables location in the model. |