Raptor™ Non-Volatile Startup

Description

This block is used to define the behavior of Non-Volatile variables on startup after reprogramming. Variables can either be reloaded with the defaults when the module is programmed, or if 'Keep Saved Values' is selected, the values of the Non-Volatile memory will be maintained from the previous program. If the structure of the Non-Volatile memory changes (variables are added or removed), then it will not be possible to keep the saved values and all Non-Volatile items will be restored to their default when the module is programmed. If this block is not present in the model, the Non-Volatile memory will be loaded with defaults when the application starts after reprogramming. If any Fixed Non-Volatile variables are defined within the model, a new tab will appear within the block's mask parameters, which will set the fixed non-volatile variables behavior after reprogramming. If Initialize Select is chosen, this setting will be forwarded to the Fixed NV Manager block.

Parameters

Parameter Type Description
Behavior After Reprogramming Specifies if the NonVolatile memory will be restored to default when a module is programmed
Access Level Sets the access level of this item in the calibration tool.