Description
This block defines a fault and set its status. The Raptor™ Fault Manager block must exist in the model to use this block.
Inputs
Input | Type | Description |
---|
Outputs
Output | Type | Description |
---|
Parameters
Parameter | Type | Description |
---|---|---|
Fault Name | String | Defines the name of the fault. Must be a valid C identifier. |
Emissions Related | Defines if the fault is emissions related. | |
Permanent | Defines if the fault is permanent. | |
Clearing Method | Determines if the fault states are cleared automatically or if the user must clear the fault states | |
X Count | Number | Input status must be true for this many count out of the last Y to set the fault as Active. |
Y Count | Number | Number of executions to track input status over. |
Calibratable X/Y Count | Allows the X, Y count limits, emissions related and permanent statuses to be changed in the calibtation tool. | |
Access Level | Sets the access level of X/Y limits in the calibration tool. | |
Function | String | Sets the location where the X/Y limit appears in the calibration tool. Use raptor_xcp_function(gcb) to create a function based on the variables location in the model. |