Raptor:OBD Ratio Increment: Difference between revisions
Jump to navigation
Jump to search
(Created page with 'Return to the main Raptor page Return to OBD Faults page right|frame|Raptor OBD Ratio Increment == D…') |
No edit summary |
||
(3 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
[[ | [[Raptor-Platform|Return to the main Raptor page]] | ||
[[Raptor:Faults(OBD)|Return to OBD Faults page]] | [[Raptor:Faults(OBD)|Return to OBD Faults page]] | ||
[[File:RaptorOBDRatioIncrement.jpg|right|frame| | [[File:RaptorOBDRatioIncrement.jpg|right|frame|Raptor™ OBD Ratio Increment]] | ||
== Description == | == Description == | ||
<p>This block increments an OBD ratio. The counters can only be incremented once each (numerator and denominator) per drive cycle regardless of the number of times the increment block is executed. This block requires the ratio to be defined with a OBD ratio definition.</p> | <p>This block increments an OBD ratio. The counters can only be incremented once each (numerator and denominator) per drive cycle regardless of the number of times the increment block is executed. This block requires the ratio to be defined with a OBD ratio definition.</p> | ||
== Parameters == | == Parameters == | ||
Line 43: | Line 27: | ||
| Enables the inhibit input port. | | Enables the inhibit input port. | ||
|} | |} | ||
Latest revision as of 20:35, 13 September 2023
Return to the main Raptor page
Description
This block increments an OBD ratio. The counters can only be incremented once each (numerator and denominator) per drive cycle regardless of the number of times the increment block is executed. This block requires the ratio to be defined with a OBD ratio definition.
Parameters
Parameter | Type | Description |
---|---|---|
Ratio Name | The name of the ratio. This must be unique. | |
Numerator/Denominator | Chooses which counter to increment. | |
Show Inhibit Port | Enables the inhibit input port. |