<p>This block shows the current status of the USB drive.</p>
<p>This block shows desired information about a USB. The user can indicate what will be shown by selecting various parameters.</p>
 
<p>It is important to utilize the outputs of this block to ensure that the USB storage device is in a "ready to log" state before opening or writing to a log file, and to ensure that the USB storage device is ready to eject before physically removing the device.</p>
 
<p>Note: Ensure that the USB storage device is ejected using a USB Eject block before physically removing the device. Removing the device without ejecting it can result in all data written to the log file since the last successful sync operation being lost.</p>
 
<p>Note: Simulink String blocks are not compatible with Raptor blocks. Please use Raptor String blocks.</p>


== Inputs ==
== Inputs ==
Line 16: Line 22:
|-
|-
! Path
! Path
| String
| r_string
| String to store the USB drive path to.
| Path of the USB. Typically provided an empty string using a raptor_string block.
|}
|}


Line 36: Line 42:
|-
|-
! Path
! Path
| String
| r_string
| The path of the USB drive.
| Gives the path (volume identifier or drive letter) to the USB device.
|-
! Ready to Log
| boolean
| Indicates whether the USB is currently ready for logging. Logging should be disabled when the output is false. After an ejection operation is initiated, this value will be false.
|}
|}


Line 48: Line 58:
|-
|-
! Show Inserted Status
! Show Inserted Status
|  
| boolean
| Enables the output port for inserted status.
| Enables the output port for inserted status.
|-
|-
! Show Eject Ready Status
! Show Eject Ready Status
|  
| boolean
| Enables the output port for eject ready status.
| Enables the output port for eject ready status.
|-
|-
! Show USB Path
! Show USB Path
|  
| string
| Enables the output port for USB path.
| Enables the output port for USB path.
|-
! Show Ready to Log Status
| boolean
| Show the port to read whether the drive is ready for logging.
|}
|}
== Supported Versions ==
* [[Raptor:Versions#2013a_0.0.1|Raptor 2013a_0.0.1]] and newer

Latest revision as of 16:30, 13 September 2023

Return to the main Raptor page

Return to File IO page

Raptor™ Display USB Status

Description

This block shows desired information about a USB. The user can indicate what will be shown by selecting various parameters.

It is important to utilize the outputs of this block to ensure that the USB storage device is in a "ready to log" state before opening or writing to a log file, and to ensure that the USB storage device is ready to eject before physically removing the device.

Note: Ensure that the USB storage device is ejected using a USB Eject block before physically removing the device. Removing the device without ejecting it can result in all data written to the log file since the last successful sync operation being lost.

Note: Simulink String blocks are not compatible with Raptor blocks. Please use Raptor String blocks.

Inputs

Input Type Description
Path r_string Path of the USB. Typically provided an empty string using a raptor_string block.

Outputs

Output Type Description
Inserted bool Indicates that a USB drive has been detected.
Eject Ready bool Indicates that the USB drive has been ejected and can be safely removed.
Path r_string Gives the path (volume identifier or drive letter) to the USB device.
Ready to Log boolean Indicates whether the USB is currently ready for logging. Logging should be disabled when the output is false. After an ejection operation is initiated, this value will be false.

Parameters

Parameter Type Description
Show Inserted Status boolean Enables the output port for inserted status.
Show Eject Ready Status boolean Enables the output port for eject ready status.
Show USB Path string Enables the output port for USB path.
Show Ready to Log Status boolean Show the port to read whether the drive is ready for logging.