Lithium-Balance-BMS: Difference between revisions
No edit summary |
No edit summary |
||
(9 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{DISPLAYTITLE: Lithium Balance BMS}} | {{DISPLAYTITLE: Lithium Balance BMS}} | ||
{| class="wikitable" style="text-align: | {| class="wikitable" style="text-align: left;" cellpadding = "5" align="left" | ||
!scope="col"|Information Type | !scope="col"|Information Type | ||
!scope="col"| | !scope="col"| | ||
|- style="vertical-align: | |- style="vertical-align:center;" | ||
|style = "width: | |style = "width:180px;"| | ||
BMS Configuration Document | BMS Configuration Document | ||
|style = "width: | |style = "width:700px;"| | ||
'''[https://www.neweagle.net/support/wiki/ProductDocumentation/EVsoftwareAndHardware/LiBal/BMS%20configuration.pdf Click Here]''' | '''[https://www.neweagle.net/support/wiki/ProductDocumentation/EVsoftwareAndHardware/LiBal/BMS%20configuration.pdf Click Here]''' | ||
|- style="vertical-align:left;" | |- style="vertical-align:left;" | ||
|style = "width: | |style = "width:180px;style="horizontal-align:left"| | ||
Basic Configuration Example | Basic Configuration Example | ||
|style = "width: | |style = "width:700px;"| | ||
Lithium Balance Basic Configuration example: | Lithium Balance Basic Configuration example: | ||
Let’s take an example. If you are building a 72V battery based on LFP cells | Let’s take an example. If you are building a 72V battery based on LFP cells at 3V nominal per cell, then you need 72V/3V = 24 cells. That is a 24C configuration. | ||
You need: | You need:<br> | ||
• 1x (LIB-BMCU-001) BMCU | • 1x (LIB-BMCU-001) BMCU<br /> | ||
• 3x (LIB-LMU-001) LMU – as each LMU covers 8 cells. | • 3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.<br /> | ||
• 1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 | • 1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 including IO wire 400mm<br /> | ||
• 3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 | • 3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 including 120mm Comm Wire and Temp Sensor<br /> | ||
• 1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO | • 1x (LIB-MGT-SW-001) Diagnostic Software v6/PRO and Inst. Manual including 5h support<br /> | ||
• | • Nx (LIB-SRV-SW-001) Diagnostic Software v6/SERVICE and Inst. Manual (Where 'N' is the number the customer needs for their service technicians: i.e., if they have one service technician, they need one.) | ||
|- style="vertical-align:middle;" | |- style="vertical-align:middle;" | ||
|style = "width: | |style = "width:180px;"| | ||
User Manual | User Manual | ||
|style = "width: | |style = "width:700px;"| | ||
'''Please contact [http://www.neweagle.net/contact/ sales]''' | |||
|-style = "width:280px;"| | |-style = "width:280px;"| | ||
|style = "width: | |style = "width:180px;"| | ||
BMS Housing Available | BMS Housing Available | ||
|style = "width: | |style = "width:700px;"| | ||
'''Please contact [http://www.neweagle.net/contact/ sales]''' | |||
|} | |} | ||
Latest revision as of 18:05, 6 February 2023
Information Type | |
---|---|
BMS Configuration Document |
|
Basic Configuration Example |
Lithium Balance Basic Configuration example: Let’s take an example. If you are building a 72V battery based on LFP cells at 3V nominal per cell, then you need 72V/3V = 24 cells. That is a 24C configuration. You need: |
User Manual |
Please contact sales |
BMS Housing Available |
Please contact sales |