Lithium-Balance-BMS: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 18: Line 18:
Lithium Balance Basic Configuration example:
Lithium Balance Basic Configuration example:


Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell. Then you need 72V/3V = 24 cells. That is a 24S configuration
Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell. Then you need 72V/3V = 24 cells. <br />That is a 24S configuration
   
   
You need:
You need:
•        1x (LIB-BMCU-001) BMCU
•        1x (LIB-BMCU-001) BMCU<br />
•        3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.
•        3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.<br />
•        1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 incl. IO wire 400mm
•        1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 incl. IO wire 400mm<br />
•        3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 incl 120mm Comm Wire + Temp.Sensor
•        3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 incl 120mm Comm Wire + Temp.Sensor<br />
•        1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual incl. 5h support
•        1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual incl. 5h support<br />
•        1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer needs for their service technicians, if they have 1 service technician they need 1)
•        1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer needs for their service technicians, <br />if they have 1 service technician they need 1)
|- style="vertical-align:middle;"
|- style="vertical-align:middle;"
|style = "width:280px;"|
|style = "width:280px;"|

Revision as of 18:55, 17 August 2017


Information Type Do This

BMS Configuration Document

Click Here

Basic Configuration Example

Lithium Balance Basic Configuration example:

Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell. Then you need 72V/3V = 24 cells.
That is a 24S configuration

You need: • 1x (LIB-BMCU-001) BMCU
• 3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.
• 1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 incl. IO wire 400mm
• 3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 incl 120mm Comm Wire + Temp.Sensor
• 1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual incl. 5h support
• 1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer needs for their service technicians,
if they have 1 service technician they need 1)

User Manual

Please contact sales

BMS Housing Available

Please contact sales