=== | === 2015-05-25: Release 2015a.0.0.1 === | ||
------------------------------------ | ------------------------------------ | ||
==== | ==== Highlights ==== | ||
This version features significant stability and performance improvements, improvements to | |||
calibrations workflows (offline calibrations in particular) and numerous UI improvements. | |||
==== | ==== Details ==== | ||
* | * [http://software.neweagle.net/issues/view.php?id=0000866 0000866] Changing CAN Baud rate causes the application to crash | ||
* | * [http://software.neweagle.net/issues/view.php?id=0000865 0000865] Opening offline display with no RPG shows cryptic error | ||
* [http://software.neweagle.net/issues/view.php?id=0000832 0000832] Extracting an online CAL with a signal to the grid creates a duplicate value in the RCAL | |||
* [http://software.neweagle.net/issues/view.php?id=0000863 0000863] Reduce default cell margins | |||
* [http://software.neweagle.net/issues/view.php?id=0000179 0000179] Signal Detail Pane | |||
* [http://software.neweagle.net/issues/view.php?id=0000838 0000838] Refreshing signals when doing offline calibration causes crash | |||
* [http://software.neweagle.net/issues/view.php?id=0000841 0000841] Explicitly allow partial calibrations | |||
* [http://software.neweagle.net/issues/view.php?id=0000856 0000856] Drag-n-drop on SignalsContainer takes wrong item | |||
* [http://software.neweagle.net/issues/view.php?id=0000858 0000858] Units cells overflow to the left | |||
* [http://software.neweagle.net/issues/view.php?id=0000859 0000859] Closing offline display dos not remove container frrom signal tree | |||
* [http://software.neweagle.net/issues/view.php?id=0000843 0000843] Reading an .rcal with duplicate signals causes the application to crash | |||
* [http://software.neweagle.net/issues/view.php?id=0000842 0000842] Show home page when all other documents are closed | |||
* [http://software.neweagle.net/issues/view.php?id=0000748 0000748] extract calibration should not try to place the values on the page | |||
* [http://software.neweagle.net/issues/view.php?id=0000711 0000711] Make UI consistent between Transfer Upgrade aed Transfer Merge | |||
* [http://software.neweagle.net/issues/view.php?id=0000837 0000837] Signal Container needs to only show signals contained in rcal when doing offline calibrations | |||
* [http://software.neweagle.net/issues/view.php?id=0000835 0000835] Drag-n-drop between DAQScheduleViewModel causes crash | |||
* [http://software.neweagle.net/issues/view.php?id=0000831 0000831] Invalid veeCAN package causes application to crash | |||
* [http://software.neweagle.net/issues/view.php?id=0000830 0000830] Remove references to RIL.UsbDriveInfo | |||
* [http://software.neweagle.net/issues/view.php?id=0000784 0000784] DAQ gets hung | |||
* [http://software.neweagle.net/issues/view.php?id=0000824 0000824] Wire in old cal workflows for patch release | |||
* [http://software.neweagle.net/issues/view.php?id=0000801 0000801] About picture says merlin and shows a merlin picture | |||
* [http://software.neweagle.net/issues/view.php?id=0000783 0000783] Merlin reference when no Kvaser connected | |||
* [http://software.neweagle.net/issues/view.php?id=0000793 0000793] Default Datalogging Output Path | |||
* [http://software.neweagle.net/issues/view.php?id=0000782 0000782] Melrin Reference in License Check | |||
* [http://software.neweagle.net/issues/view.php?id=0000864 0000864] Remove unit text frrom the grid | |||
* [http://software.neweagle.net/issues/view.php?id=0000833 0000833] Various drag-n-drop actions in the DAQ lists cause the application to hang | |||
* [http://software.neweagle.net/issues/view.php?id=0000825 0000825] First 2015a release will also accept 2014b licenses | |||
=== 2015-03-16: Release 2014b.0.1.10 === | |||
------------------------------------ | |||
* 0000780: Ability to recover Motohawk modules in hardboot | |||
* 0000779: Connection and reflash are broken | |||
=== 2015-03-16: Release 2014b.0.1.9 === | |||
------------------------------------ | |||
* 0000772: Add shortcut to Motohawk Packager frrom Merlin UI | |||
* 0000770: Moving items between daqs throws an exception | |||
* 0000640: Merlin display signals to display values as Hex or Decimal | |||
* 0000769: Indicate signal direction in signal select | |||
* 0000737: A, B, C, D for column headers | |||
* 0000761: Corrupted RecentFiles.xml causes the application to crash | |||
* 0000760: Setting value on disconnected XCP module causes the application to crash | |||
* 0000719: RDIS files don't use the default RDIS directory | |||
* 0000676: Long status messages are unreadble | |||
* 0000673: Ctrl*s to save current display | |||
* 0000646: MotoHawk modules need offline support | |||
* 0000645: Notify UI of lost MIL Connection | |||
* 0000687: SignalGridViewModel._signalsOnGrid need to be handled by name and not object reference | |||
* 0000628: name tabs better when editing a can offline | |||
* 0000654: upload online cal should be done in a dialog | |||
* 0000694: create a "fast" query list | |||
* 0000575: add ability to rearrange signals on grid w/ drag and drop | |||
* 0000585: visually distinguish labels frrom data | |||
* 0000663: CAN monitor should distinguish between error frames and loaded CAN bus | |||
* 0000668: CAN traffic monitors stop working after Kvaser USB is removed and then restored | |||
* 0000660: adding second CAN channel requires Merlin restart before it is accessable | |||
* 0000649: table signals should have as many sub signals as possible collected under them in the signal tree | |||
* 0000695: deleting one instance of a signal frrom the grid removes the signal frrom RDIS | |||
* 0000672: save calibration tool bar button's tool tip says "Save Calibration Command" | |||
* 0000680: Display signal 'Help Text' (LongIdentifier in A2L) as the tooltip shown when mouse over a signal in a display. | |||
* 0000583: application monitor signals not correct | |||
=== 2015-01-26: Release 2014b.0.1.8 === | |||
------------------------------------ | |||
* Added limited support for MotoHawk module connectivity (no cal workflows, only a selection of modules) | |||
* Improved Merlin's handling of very heavy CAN busses: | |||
** Notifications when there is enough CAN traffic that communications with the module might not be reliable | |||
** Notifications when DAQ packets are being dropped | |||
* Added basic data logging: | |||
** Record and stop buttons in tool bar | |||
** Records all scalar-sized signals to a CSV file | |||
* Added support for node-locked licenses | |||
* Added cell-justification formatting options | |||
* Display files preserve cell-justification and DAQ schedule | |||
* Improvements to DAQ scheduling: | |||
** Drag-and-drop signals between the DAQs and Queries | |||
** Signals that don't fit on a DAQ are cascaded down to slower DAQs | |||
** Signals are put on the slowest DAQ by default (instead of the fastest) | |||
* Various UI improvements and bug fixes | |||
=== 2014-12-19: Release 2014b.0.1.7 === | |||
------------------------------------ | |||
* Window layout is preserved bewteen sessions | |||
* Added ability to perform interpolation to modify calibration values | |||
* Signal tree shows signals sorted by name | |||
* Display and Calibration files can be opened in Merlin by opening them in Windows Explorer | |||
* Displays in list of most recent displays on start page can be removed | |||
* Bug fixes and stability improvements | |||
* UI improvements | |||
=== 2014-12-17: Release 2014b.0.1.6 === | |||
* | ------------------------------------ | ||
* | * Added merge and transfer-upgrade calibrations workflows | ||
* | * Added upgrade displays workflow | ||
* | * Display files now preserve row and column sizing | ||
* | * Various bug fixes and UI improvements | ||
* | |||
* | |||
* | === 2014-11-20: Release 2014b.0.1.5 === | ||
* | ------------------------------------ | ||
* Fixed some bugs in table display | |||
* Merlin now supports signals-only packages for VeeCAN targets (generated when building just for the VeeCAN simulator) | |||
* Improvements to the display grid: | |||
** The selected cell is now highlighted | |||
** Data entry is easier | |||
** Arrow key navigation works better | |||
* Models with non-standard DAQ configurations are better supported | |||
* Offline calibration extraction frrom RPG files feature added | |||
=== 2014-11-04: Release 2014b.0.1.3 === | |||
------------------------------------ | |||
* Fixed crash when dragging external files onto Merlin grid | |||
* Cleaned up UI when dragging large signal groups onto grid | |||
* Fixed crash when refreshing signals when editing an offline calibration | |||
* Adding new signals into an offline calibration shows the values frrom the RPG | |||
* Only calibratable signals appear in the signals pane when editing an offline calibration | |||
=== 2014-10-31: Release 2014b.0.1.1 === | |||
------------------------------------ | |||
* Offline calibration editing is supported | |||
* Fixed some issues with offline display editing | |||
* Fixed issues with having the same signal on the grid more than once | |||
* Updated the UI to have improved/consistent icons in the menus and toolbar | |||
* Merlin handles power-cycling modules while connected | |||
* Merlin is be able to reflash modules that are not accessible via XCP | |||
* Removed CHM-based help and replaced with a browser-based help (content still under work) | |||
* Improved handling of invalid RPG files | |||
=== 2014-10-28: Release 2014b.0.0.14 === | |||
------------------------------------ | |||
* Fixed issue with reading large tables (> 255 bytes) | |||
* Fixed issue with table indexing | |||
* Added support for XCP access levels |
Revision as of 17:17, 16 November 2017
2015-05-25: Release 2015a.0.0.1
Highlights
This version features significant stability and performance improvements, improvements to calibrations workflows (offline calibrations in particular) and numerous UI improvements.
Details
- 0000866 Changing CAN Baud rate causes the application to crash
- 0000865 Opening offline display with no RPG shows cryptic error
- 0000832 Extracting an online CAL with a signal to the grid creates a duplicate value in the RCAL
- 0000863 Reduce default cell margins
- 0000179 Signal Detail Pane
- 0000838 Refreshing signals when doing offline calibration causes crash
- 0000841 Explicitly allow partial calibrations
- 0000856 Drag-n-drop on SignalsContainer takes wrong item
- 0000858 Units cells overflow to the left
- 0000859 Closing offline display dos not remove container frrom signal tree
- 0000843 Reading an .rcal with duplicate signals causes the application to crash
- 0000842 Show home page when all other documents are closed
- 0000748 extract calibration should not try to place the values on the page
- 0000711 Make UI consistent between Transfer Upgrade aed Transfer Merge
- 0000837 Signal Container needs to only show signals contained in rcal when doing offline calibrations
- 0000835 Drag-n-drop between DAQScheduleViewModel causes crash
- 0000831 Invalid veeCAN package causes application to crash
- 0000830 Remove references to RIL.UsbDriveInfo
- 0000784 DAQ gets hung
- 0000824 Wire in old cal workflows for patch release
- 0000801 About picture says merlin and shows a merlin picture
- 0000783 Merlin reference when no Kvaser connected
- 0000793 Default Datalogging Output Path
- 0000782 Melrin Reference in License Check
- 0000864 Remove unit text frrom the grid
- 0000833 Various drag-n-drop actions in the DAQ lists cause the application to hang
- 0000825 First 2015a release will also accept 2014b licenses
2015-03-16: Release 2014b.0.1.10
- 0000780: Ability to recover Motohawk modules in hardboot
- 0000779: Connection and reflash are broken
2015-03-16: Release 2014b.0.1.9
- 0000772: Add shortcut to Motohawk Packager frrom Merlin UI
- 0000770: Moving items between daqs throws an exception
- 0000640: Merlin display signals to display values as Hex or Decimal
- 0000769: Indicate signal direction in signal select
- 0000737: A, B, C, D for column headers
- 0000761: Corrupted RecentFiles.xml causes the application to crash
- 0000760: Setting value on disconnected XCP module causes the application to crash
- 0000719: RDIS files don't use the default RDIS directory
- 0000676: Long status messages are unreadble
- 0000673: Ctrl*s to save current display
- 0000646: MotoHawk modules need offline support
- 0000645: Notify UI of lost MIL Connection
- 0000687: SignalGridViewModel._signalsOnGrid need to be handled by name and not object reference
- 0000628: name tabs better when editing a can offline
- 0000654: upload online cal should be done in a dialog
- 0000694: create a "fast" query list
- 0000575: add ability to rearrange signals on grid w/ drag and drop
- 0000585: visually distinguish labels frrom data
- 0000663: CAN monitor should distinguish between error frames and loaded CAN bus
- 0000668: CAN traffic monitors stop working after Kvaser USB is removed and then restored
- 0000660: adding second CAN channel requires Merlin restart before it is accessable
- 0000649: table signals should have as many sub signals as possible collected under them in the signal tree
- 0000695: deleting one instance of a signal frrom the grid removes the signal frrom RDIS
- 0000672: save calibration tool bar button's tool tip says "Save Calibration Command"
- 0000680: Display signal 'Help Text' (LongIdentifier in A2L) as the tooltip shown when mouse over a signal in a display.
- 0000583: application monitor signals not correct
2015-01-26: Release 2014b.0.1.8
- Added limited support for MotoHawk module connectivity (no cal workflows, only a selection of modules)
- Improved Merlin's handling of very heavy CAN busses:
- Notifications when there is enough CAN traffic that communications with the module might not be reliable
- Notifications when DAQ packets are being dropped
- Added basic data logging:
- Record and stop buttons in tool bar
- Records all scalar-sized signals to a CSV file
- Added support for node-locked licenses
- Added cell-justification formatting options
- Display files preserve cell-justification and DAQ schedule
- Improvements to DAQ scheduling:
- Drag-and-drop signals between the DAQs and Queries
- Signals that don't fit on a DAQ are cascaded down to slower DAQs
- Signals are put on the slowest DAQ by default (instead of the fastest)
- Various UI improvements and bug fixes
2014-12-19: Release 2014b.0.1.7
- Window layout is preserved bewteen sessions
- Added ability to perform interpolation to modify calibration values
- Signal tree shows signals sorted by name
- Display and Calibration files can be opened in Merlin by opening them in Windows Explorer
- Displays in list of most recent displays on start page can be removed
- Bug fixes and stability improvements
- UI improvements
2014-12-17: Release 2014b.0.1.6
- Added merge and transfer-upgrade calibrations workflows
- Added upgrade displays workflow
- Display files now preserve row and column sizing
- Various bug fixes and UI improvements
2014-11-20: Release 2014b.0.1.5
- Fixed some bugs in table display
- Merlin now supports signals-only packages for VeeCAN targets (generated when building just for the VeeCAN simulator)
- Improvements to the display grid:
- The selected cell is now highlighted
- Data entry is easier
- Arrow key navigation works better
- Models with non-standard DAQ configurations are better supported
- Offline calibration extraction frrom RPG files feature added
2014-11-04: Release 2014b.0.1.3
- Fixed crash when dragging external files onto Merlin grid
- Cleaned up UI when dragging large signal groups onto grid
- Fixed crash when refreshing signals when editing an offline calibration
- Adding new signals into an offline calibration shows the values frrom the RPG
- Only calibratable signals appear in the signals pane when editing an offline calibration
2014-10-31: Release 2014b.0.1.1
- Offline calibration editing is supported
- Fixed some issues with offline display editing
- Fixed issues with having the same signal on the grid more than once
- Updated the UI to have improved/consistent icons in the menus and toolbar
- Merlin handles power-cycling modules while connected
- Merlin is be able to reflash modules that are not accessible via XCP
- Removed CHM-based help and replaced with a browser-based help (content still under work)
- Improved handling of invalid RPG files
2014-10-28: Release 2014b.0.0.14
- Fixed issue with reading large tables (> 255 bytes)
- Fixed issue with table indexing
- Added support for XCP access levels