GCM-5605B-048 (GCM48)
The GCM 48 is a general-purpose control module with six CAN buses, two LIN masters and one LIN slave, and configurable discrete inputs and outputs including analog inputs, frequency inputs, a wake input, low-side driver outputs and an H-bridge driver output.
The GCM 48 is one of the Raptor rugged production controllers that use a software development process based on MATLAB/Simulink and Raptor-Dev which significantly speeds up algorithm development by using automatic integration and code generation. In addition, developers can quickly test application software using simulation and automated testing.
Datasheets
- GCM-5605B-048-2008
- GCM-5605B-048-2104
Frequently Asked Questions
Q: LIN1 & LIN2 Communication issues?
A:It was discovered that in the 2002 and 2008 Revisions, that the LIN1 and LIN2 resources are swapped. Previous documentation was incorrect and the datasheet now reflects the proper pin-out.
If you are transitioning your system from a 2002 or 2008 to a 2104 and use LIN1 or LIN2, you will need to swap these pins.
Q: What is the Baud Rate for Recovery of the GCM48?
A:Recovery Procedure is CAN 1, 500K Baud Rate The GCM48 boot procedure only works at 500K Baud only.
Q: Can I flash the GCM48 on different CAN buses?
A: The GCM48-1906 and GCM48-2002 variants of the GCM48 can only be flashed on CAN1 with a fixed address. The GCM48-2008 and GCM48-2104 support flashing on different CAN buses.
Q: What is new in the GCM48-2104?
A: The GCM48-2104 only utilizes 7 Low-Side Outputs. In this variant, LSO6 is utilized for "Fuel Level Indicator" actuation and is not able to function as a typical LSO.
Q: How much current does the module sink when hibernating? How much does it sink when not hibernating?
A: When WAKE_INPUT1 is low, the module draws about 550uA. When WAKE_INPUT1 is high (module is on), it draws about 120mA.
Q: Are there other user tips and Q&A on Raptor ECUs published?
A: Yes, see the knowledge base on the support portal. https://neweagle.net/product-support/
Compiler
S32 Design Studio for Power Architecture v2.1
Please reference the following Document to download and install the compiler from NXP's website.
GCM48 Compiler Installation Guide
Obsolete Modules
- GCM-5605B-048-2002