Line 18: Line 18:
Lithium Balance Basic Configuration example:
Lithium Balance Basic Configuration example:


Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell. <br />Then you need 72V/3V = 24 cells. That is a 24S configuration
Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell, then you need 72V/3V = 24 cells. That is a 24C configuration.
   
   
You need:
You need:
•        1x (LIB-BMCU-001) BMCU<br />
•        1x (LIB-BMCU-001) BMCU<br />
•        3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.<br />
•        3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.<br />
•        1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 incl. IO wire 400mm<br />
•        1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 including IO wire 400mm<br />
•        3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 incl 120mm Comm Wire + Temp.Sensor<br />
•        3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 including 120mm Comm Wire + Temp Sensor<br />
•        1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual incl. 5h support<br />
•        1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual including 5h support<br />
•        1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer <br />needs for their service technicians, if they have 1 service technician they need 1)
•        1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer needs for their service technicians, if they have one service technician, they need one.)
|- style="vertical-align:middle;"
|- style="vertical-align:middle;"
|style = "width:180px;"|
|style = "width:180px;"|

Revision as of 21:12, 2 February 2023


Information Type

BMS Configuration Document

Click Here

Basic Configuration Example

Lithium Balance Basic Configuration example:

Let’s take an example. If you are building a 72V battery based on LFP cells @ 3V nominal/each cell, then you need 72V/3V = 24 cells. That is a 24C configuration.

You need: • 1x (LIB-BMCU-001) BMCU
• 3x (LIB-LMU-001) LMU – as each LMU covers 8 cells.
• 1x (LIB-HARKIT-BMCU-01) Harness kit for BMCU v6 including IO wire 400mm
• 3x (LIB-HARNKIT-LMU-01) Harness kit for LMU v6 including 120mm Comm Wire + Temp Sensor
• 1x (LIB-MGT-SW-001) Diagnostic Software v6 / PRO + Inst. Manual including 5h support
• 1x (LIB-SRV-SW-001) Diagnostic Software v6 / SERVICE + Inst. Manual (N is the numbers the customer needs for their service technicians, if they have one service technician, they need one.)

User Manual

Please contact sales

BMS Housing Available