MiniView: Difference between revisions
No edit summary |
|||
Line 15: | Line 15: | ||
== Application Note == | == Application Note == | ||
=== CAN === | |||
MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk block set). The CAN ID’s are also not configurable. | MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk block set). The CAN ID’s are also not configurable. | ||
=== Interface Protection === | |||
The interface circuits and the electronic device connected to the network are designed to withstand over voltage and wiring errors. | |||
No permanent damage shall result from a voltage level of +/- 18 Volts applied between any two wires in the interface for an indefinite period of time. | |||
No permanent damage shall result from miswiring the interface lines in any combination for an indefinite time. | |||
==Libraries== | ==Libraries== |
Revision as of 21:09, 20 July 2011
MotoHawk's MiniView
This rugged display unit is capable of operating in harsh marine and off-highway applications. Designed to operate with the MotoHawk® line of rugged controllers, the circular display (65 pixels high, 65 pixels wide, 4 built-in fonts, adjustable backlight) is controlled from the customer application via the MiniView CAN interface, typically using the MotoHawk® block set.
- Features include:
- Low operating temperature (-40 degrees)
- CANbus data link
- Comes with SmartCraft connector
- IP-X7 Marine Protection Rating
- Rugged Case
Application Note
CAN
MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk block set). The CAN ID’s are also not configurable.
Interface Protection
The interface circuits and the electronic device connected to the network are designed to withstand over voltage and wiring errors.
No permanent damage shall result from a voltage level of +/- 18 Volts applied between any two wires in the interface for an indefinite period of time.
No permanent damage shall result from miswiring the interface lines in any combination for an indefinite time.
Libraries
Bar Graph
Datasheets
Datasheet errata
The operating temperature is actually -40 to +85 degrees Celsius. (incorrect in datasheet as of December 17, 2010)