CAN Relay Box

The New Eagle™ Multiplexed Power Distribution Module offers economical CAN Network oversight for high power circuits in vehicle power distribution. Manufactured as a hardened and weather tight module, it may be configured to provide various OEM circuit protection and switching functions, using industry standard fuses, relays and breakers, with the status and control of each circuit accessible through J1939/CAN open messages.

Highlights

High Power - This module uses a technology that is ideal for high current circuits and networking electronics. Each module is rated up to 30 A, and a maximum of 32 outputs are possible with it. 12 and 24 volt systems are both supported on this module.

Ruggedness – Waterproof to high pressure spraying, this module is designed and manufactured with robust features such as heavy duty housing, silicon and Gortex gasketing, and protective conformal coated electronics, to operate in demanding vehicle environments such as those found in construction, agriculture, heavy truck, bus, RV, marine and specialty vehicle markets.

Flexibility – This module is offered in various standard and customized versions, with custom versions being configured to OEM wiring requirements. It accepts relays, fuses, circuit breakers, resistors, diodes etc based on the industry standard 2.8 mm footprint. Not only that, the software works with MotoHawk and New Eagle offers a pre-programmed application library to facilitate seamless integration with systems being developed on the same platform.

Product Information

Features include:
  • Operating Voltage of 9-32V
  • Max Current Capacity of 200 Amps
  • Max Current Capacity per output pin 30 Amps
  • Max Relays/ Fuses 12/32
  • Operating Temperature -40 to +85 deg C
  • Ingress Protection is IP66 equivalent
  • Foot torque rating of 60 in-lbs w/o compression limiters; 200-300 with limiters
  • CAN - Uses AMP SSC 12-position sealed connector
  • Mounting - Compression Limiters on mounting feet
Inputs:
  • Studded Input Option: Supports two M8 input power studs for DC Power into the module power grid (100 A max/stud)
  • Connectorized: Accepts up to two Bussmann 32004 connectors
  • 60 A max per terminal, providing power to the Vehicle Electrical Center power grid, uses Packard 800 series terminals
Outputs:
  • Standard Bussmann connectors
  • 8 way, colored/keyed, sealed connectors
  • 30 Amps max per terminal
  • Accepts Packard Metri-Pak 280 series terminals

Connector Details

Component Part Number Description Quantity Manufacturer Connectors
Plug Housing xxx xxx xxx xxx xxx
Replaceable Contact xxx xxx xxx xxx xxx
Double Lock Plate xxx xxx xxx xxx xxx
Wire Seal xxx xxx xxx xxx xxx
Cavity Plug xxx xxx xxx xxx xxx