Below is a list of all Raptor-Cal versions and their change logs, beginning with the most recent version.

Merlin Release Notes:

2015-03-16: Release 2014b.0.1.10


- 0000780: Ability to recover Motohawk modules in hardboot - 0000779: Connection and reflash are broken


2015-03-16: Release 2014b.0.1.9


- 0000772: Add shortcut to Motohawk Packager from Merlin UI - 0000770: Moving items between daqs throws an exception - 0000640: Merlin display signals to display values as Hex or Decimal - 0000769: Indicate signal direction in signal select - 0000737: A, B, C, D for column headers - 0000761: Corrupted RecentFiles.xml causes the application to crash - 0000760: Setting value on disconnected XCP module causes the application to crash - 0000719: RDIS files don't use the default RDIS directory - 0000676: Long status messages are unreadble - 0000673: Ctrl-s to save current display - 0000646: MotoHawk modules need offline support - 0000645: Notify UI of lost MIL Connection - 0000687: SignalGridViewModel._signalsOnGrid need to be handled by name and not object reference - 0000628: name tabs better when editing a can offline - 0000654: upload online cal should be done in a dialog - 0000694: create a "fast" query list - 0000575: add ability to rearrange signals on grid w/ drag and drop - 0000585: visually distinguish labels from data - 0000663: CAN monitor should distinguish between error frames and loaded CAN bus - 0000668: CAN traffic monitors stop working after Kvaser USB is removed and then restored - 0000660: adding second CAN channel requires Merlin restart before it is accessable - 0000649: table signals should have as many sub signals as possible collected under them in the signal tree - 0000695: deleting one instance of a signal from the grid removes the signal from RDIS - 0000672: save calibration tool bar button's tool tip says "Save Calibration Command" - 0000680: Display signal 'Help Text' (LongIdentifier in A2L) as the tooltip shown when mouse over a signal in a display. - 0000583: application monitor signals not correct


2015-01-26: Release 2014b.0.1.8


Added limited support for MotoHawk module connectivity (no cal workflows, only a selection of modules) Improved Merlin's handling of very heavy CAN busses: Notifications when there is enough CAN traffic that communications with the module might not be reliable Notifications when DAQ packets are being dropped Added basic data logging: Record and stop buttons in tool bar Records all scalar-sized signals to a CSV file Added support for node-locked licenses Added cell-justification formatting options Display files preserve cell-justification and DAQ schedule Improvements to DAQ scheduling: Drag-and-drop signals between the DAQs and Queries Signals that don't fit on a DAQ are cascaded down to slower DAQs Signals are put on the slowest DAQ by default (instead of the fastest) Various UI improvements and bug fixes


2014-12-19: Release 2014b.0.1.7


Window layout is preserved bewteen sessions Added ability to perform interpolation to modify calibration values Signal tree shows signals sorted by name Display and Calibration files can be opened in Merlin by opening them in Windows Explorer Displays in list of most recent displays on start page can be removed Bug fixes and stability improvements UI improvements


2014-12-17: Release 2014b.0.1.6


Added merge and transfer-upgrade calibrations workflows Added upgrade displays workflow Display files now preserve row and column sizing Various bug fixes and UI improvements


2014-11-20: Release 2014b.0.1.5


Fixed some bugs in table display Merlin now supports signals-only packages for VeeCAN targets (generated when building just for the VeeCAN simulator) Improvements to the display grid: - The selected cell is now highlighted - Data entry is easier - Arrow key navigation works better Models with non-standard DAQ configurations are better supported Offline calibration extraction from RPG files feature added

2014-11-04: Release 2014b.0.1.3


Fixed crash when dragging external files onto Merlin grid Cleaned up UI when dragging large signal groups onto grid Fixed crash when refreshing signals when editing an offline calibration Adding new signals into an offline calibration shows the values from the RPG Only calibratable signals appear in the signals pane when editing an offline calibration


2014-10-31: Release 2014b.0.1.1


Offline calibration editing is supported Fixed some issues with offline display editing Fixed issues with having the same signal on the grid more than once Updated the UI to have improved/consistent icons in the menus and toolbar Merlin handles power-cycling modules while connected Merlin is be able to reflash modules that are not accessible via XCP Removed CHM-based help and replaced with a browser-based help (content still under work) Improved handling of invalid RPG files


2014-10-28: Release 2014b.0.0.14


Fixed issue with reading large tables (> 255 bytes) Fixed issue with table indexing Added support for XCP access levels