Raptor-Cal-Release-Notes
New Eagle > Products Wiki > Raptor Platform > Raptor-Cal > Raptor Cal Release Notes
Below is a list of all Raptor-Cal versions and their change logs, beginning with the most recent version.
2015-03-16: Release 2014b.0.1.10
- 0000780: Ability to recover Motohawk modules in hardboot
- 0000779: Connection and reflash are broken
2015-03-16: Release 2014b.0.1.9
- 0000772: Add shortcut to Motohawk Packager from Merlin UI
- 0000770: Moving items between daqs throws an exception
- 0000640: Merlin display signals to display values as Hex or Decimal
- 0000769: Indicate signal direction in signal select
- 0000737: A, B, C, D for column headers
- 0000761: Corrupted RecentFiles.xml causes the application to crash
- 0000760: Setting value on disconnected XCP module causes the application to crash
- 0000719: RDIS files don't use the default RDIS directory
- 0000676: Long status messages are unreadble
- 0000673: Ctrl*s to save current display
- 0000646: MotoHawk modules need offline support
- 0000645: Notify UI of lost MIL Connection
- 0000687: SignalGridViewModel._signalsOnGrid need to be handled by name and not object reference
- 0000628: name tabs better when editing a can offline
- 0000654: upload online cal should be done in a dialog
- 0000694: create a "fast" query list
- 0000575: add ability to rearrange signals on grid w/ drag and drop
- 0000585: visually distinguish labels from data
- 0000663: CAN monitor should distinguish between error frames and loaded CAN bus
- 0000668: CAN traffic monitors stop working after Kvaser USB is removed and then restored
- 0000660: adding second CAN channel requires Merlin restart before it is accessable
- 0000649: table signals should have as many sub signals as possible collected under them in the signal tree
- 0000695: deleting one instance of a signal from the grid removes the signal from RDIS
- 0000672: save calibration tool bar button's tool tip says "Save Calibration Command"
- 0000680: Display signal 'Help Text' (LongIdentifier in A2L) as the tooltip shown when mouse over a signal in a display.
- 0000583: application monitor signals not correct
2015-01-26: Release 2014b.0.1.8
- Added limited support for MotoHawk module connectivity (no cal workflows, only a selection of modules)
- Improved Merlin's handling of very heavy CAN busses:
- Notifications when there is enough CAN traffic that communications with the module might not be reliable
- Notifications when DAQ packets are being dropped
- Added basic data logging:
- Record and stop buttons in tool bar
- Records all scalar-sized signals to a CSV file
- Added support for node-locked licenses
- Added cell-justification formatting options
- Display files preserve cell-justification and DAQ schedule
- Improvements to DAQ scheduling:
- Drag-and-drop signals between the DAQs and Queries
- Signals that don't fit on a DAQ are cascaded down to slower DAQs
- Signals are put on the slowest DAQ by default (instead of the fastest)
- Various UI improvements and bug fixes
2014-12-19: Release 2014b.0.1.7
- Window layout is preserved bewteen sessions
- Added ability to perform interpolation to modify calibration values
- Signal tree shows signals sorted by name
- Display and Calibration files can be opened in Merlin by opening them in Windows Explorer
- Displays in list of most recent displays on start page can be removed
- Bug fixes and stability improvements
- UI improvements
2014-12-17: Release 2014b.0.1.6
- Added merge and transfer-upgrade calibrations workflows
- Added upgrade displays workflow
- Display files now preserve row and column sizing
- Various bug fixes and UI improvements
2014-11-20: Release 2014b.0.1.5
- Fixed some bugs in table display
- Merlin now supports signals-only packages for VeeCAN targets (generated when building just for the VeeCAN simulator)
- Improvements to the display grid:
- The selected cell is now highlighted
- Data entry is easier
- Arrow key navigation works better
- Models with non-standard DAQ configurations are better supported
- Offline calibration extraction from RPG files feature added
2014-11-04: Release 2014b.0.1.3
- Fixed crash when dragging external files onto Merlin grid
- Cleaned up UI when dragging large signal groups onto grid
- Fixed crash when refreshing signals when editing an offline calibration
- Adding new signals into an offline calibration shows the values from the RPG
- Only calibratable signals appear in the signals pane when editing an offline calibration
2014-10-31: Release 2014b.0.1.1
- Offline calibration editing is supported
- Fixed some issues with offline display editing
- Fixed issues with having the same signal on the grid more than once
- Updated the UI to have improved/consistent icons in the menus and toolbar
- Merlin handles power-cycling modules while connected
- Merlin is be able to reflash modules that are not accessible via XCP
- Removed CHM-based help and replaced with a browser-based help (content still under work)
- Improved handling of invalid RPG files
2014-10-28: Release 2014b.0.0.14
- Fixed issue with reading large tables (> 255 bytes)
- Fixed issue with table indexing
- Added support for XCP access levels