Raptor:DM7

From NewEagleWiki
Jump to navigation Jump to search

Return to the main Raptor page

Return to DM Messages page

Raptor™ DM7

Description

This block implements PGN 58112 Command Non-Continuously Monitored Test (DM7). This block implements the base of the DM7 message. Additional blocks will be needed inside to interface to the correct code to perform the requested test. Without modification, no tests are supported and all requests will cause a NACK response. The block will indicate, based on the Test Identifier if a DM8 or DM30 response is required, based on J1939-73 5.7.7.1 (Test Identifier).

Outputs

Output Type Description
DM8Fcn function call Trigger indicates that a DM8 response is requested.
DM30Fcn function call Trigger indicates that a DM30 response is requested.
SPN uint32 SPN identifying component / system for test.
Test ID uint8 Test identifier requested.
Failure Model ID uint16 FMI Identifying Component / System Specific Test

Parameters

Parameter Type Description
J1939 Bus Name String This is the name of the J1939 bus.