Raptor:Getting Started: Difference between revisions

From NewEagleWiki
Jump to navigation Jump to search
 
(108 intermediate revisions by 12 users not shown)
Line 1: Line 1:
{{Navigation}} [[Raptor-Platform | Raptor Platform]] > [[Raptor-Dev]] > '''Getting Started with Raptor-Dev'''
{{Navigation}} [[Raptor-Platform | Raptor Platform]] > [[Raptor-Dev]] > '''Getting Started with Raptor-Dev'''
=Getting Started=
 
==Downloading Raptor Software==
If you have already purchased a software license, you can download the latest release of the Raptor-Dev software at [https://software.neweagle.net/issues/login_page.php software.neweagle.net].
 
==Installation==
==Installation==


[[file:NewEagleLicenseViewer.jpg|thumb|250px|New Eagle License Viewer]]
[[file:NewEagleLicenseViewer.jpg|thumb|250px|New Eagle License Viewer]]
[[file:RaptorConfigurationEditor.jpg|thumb|250px|Raptor Configuration Editor]]
[[file:RaptorConfigurationEditor.jpg|thumb|250px|Raptor Configuration Editor]]
=====System Requirements=====
{| class="wikitable"
|-
! '''Component'''
! '''Minimum'''
|-
|Processor
|Intel compatible 2.0 GHz
|-
|RAM
| 4 GB (8 GB recommended)
|-
|Disk
|
  {|
  |Raptor-Dev
  |600 MB
  |-
  |Raptor-Cal
  |300 MB
  |-
  |Raptor-Service
  |290 MB
  |-
  |Raptor-CAN
  |10 MB
  |-
  |Raptor-Test
  |15 MB
  |}
|-
| Operating system
| Windows 10/8.1/7 64-bit
|-
| Additional requirements
| .NET Framework 4.5 - Installed with Raptor products, if not previously installed.
|}
=====Prerequisites=====
=====Prerequisites=====
* MATLAB/Simulink
** Raptor™ requires a compatible installation of MATLAB/Simulink in order to create models for code generation. MATLAB/Simulink release 2012a 32/64 bit and newer are supported. The following tools from Mathworks are required:
***MATLAB
***Simulink
***Embedded Coder
***MATLAB Coder
***Simulink Coder
***Stateflow (Optional)


* Compiler
{| class="wikitable"
** To compile the generated code properly for your embedded platform, the appropriate compiler and associated license will be required.
|-
***The BCM48, CM0711, CM3626, and CM2115 use the '''CodeWarrior for MPC55xx/MPC56xx Microcontrollers V2.10 compiler'''. You can download an evaluation version or purchase the compiler [http://www.nxp.com/products/software-and-tools/software-development-tools/codewarrior-development-tools/codewarrior-development-studios/codewarrior-for-microcontrollers/codewarrior-development-studio-for-mpc55xx-mpc56xx-classic-ide-v2.10:CW-MPC55XX_56XX here].
! '''Required:'''
***The CM3620 uses the '''IAR Embedded Workbench for ARM 4.42A''' compiler. You can download an evaluation version or purchase the compiler [https://www.iar.com/iar-embedded-workbench/#!?architecture=ARM here]
! '''Recommended:'''
*** The GCM196 and ECM196 use the '''Hightec Compiler for the Infineon TriCore architecture v3.4.5.11''' compiler. You download an evaluation version [https://www.hightec-rt.com/en/downloads/evaluation-version.html#document-tricore-aurix-development-platform-1 here] or [mailto:sales@hightec-rt.com e-mail sales] for purchase.
! '''Options:'''
|-
|style = "width: 200px"| Mathworks Software (See below)
|style = "width: 200px"| [https://store.neweagle.net/product-category/raptor/raptor-hardware/raptor-controllers-with-software/ 2nd Controller]
|style = "width: 200px"| [[Data-Loggers|CAN Data Logger]]
|-
| [[Raptor-Dev| Raptor-Dev Software or Kit]]
| [https://store.neweagle.net/product/boot-key-for-ecm555-48-80-gcm563-48-hcm563-48-ecm565-128-and-ecm5554-112/ Boot Device/Harness]
| [[Displays#Raptor_Displays|Display]]
|-
| [[Controllers#Raptor_Controllers|Control Module]]
| [https://store.neweagle.net/product-category/products/connectors-tools/crimp-removal-tools-connectors-tools/?filters=crimp-removal-tools-type Crimp Tools]
| [[Raptor-Telematics|Telematics]]
|-
| Compiler (See Below)
| [[Raptor-Cal|Raptor-Cal]]
| [[Raptor-Service|Raptor-Service]]
|-
| [[Raptor-Module-Harness-and-Connectors|Wiring, Harnesses and Connectors]]
| [[Raptor-Training|Training or Consulting]]
| [[Raptor-CAN|Raptor-CAN]]
|-
|
| Break-Out Box
| [[Raptor-Test|Raptor-Test]]
|}


===== MATLAB/Simulink Requirements =====
* Raptor requires a compatible installation of MATLAB/Simulink in order to create models for code generation. The following tools from Mathworks are required:
**MATLAB
**Simulink
**Embedded Coder
**MATLAB Coder
**Simulink Coder
**Stateflow
=====Compilers=====
*To compile the generated code properly for your embedded platform, the appropriate compiler and associated license will be required. For instance, Raptor targets with a Freescale 55xx Microprocessor will require the CodeWarrior 55xx compiler.
**The CM0711 uses the '''CodeWarrior for MPC55xx/MPC56xx Microcontrollers V2.10 compiler'''. You can download an evaluation version or purchase the compiler '''[http://www.nxp.com/products/software-and-tools/software-development-tools/codewarrior-development-tools/codewarrior-development-studios/codewarrior-for-microcontrollers/codewarrior-development-studio-for-mpc55xx-mpc56xx-classic-ide-v2.10:CW-MPC55XX_56XX here]'''.
**The GCM48, RCM80 and M47 use the '''S32DS for Power Architecture, Version V2.1'''.  This is a free download from NXP; please see our '''[https://wiki.neweagle.net/ProductDocumentation/Raptor/Controllers/S32%20Design%20Studio%20for%20Power%20Architecture%20v2.1%20Compiler%20Install%20Guide.pdf S32DS Compiler Guide]''' for installation help.
**The GCM56, GCM111 and other Aurix based controllers use the HIGHTEC-DP-TC-NL available from the New Eagle store.
**The RCM112, for prototype or non-FuSA applications, uses the GCC compiler included in '''SPC5-STUDIO'''.  This is a free download from ST; please see '''[https://www.st.com/en/development-tools/spc5-studio.html SPC5-STUDIO]''' for a link to the latest installer.
**The RCM112, for FuSA applications, will use the HighTec PowerPC compiler available from Hitex.
**The GCM196 and ECM196 use the '''Hightec Compiler for the Infineon TriCore architecture v3.4.5.11''' compiler, HIGHTEC-DP-TC, purchased from the New Eagle store.
**The GCM70 use the [[GCM-5634M-70-1459#Compiler | '''GCC PowerPC EABI 4.6.0 SPE''']] compiler.  This is a free download.
**For VeeCAN targets, use the GNU Compiler Collection (GCC) which is included free as an option in the Raptor installation process.


* .NET Framework
* .NET Framework
** Raptor requires the .NET framework from Microsoft that comes preinstalled on most current version of the Windows platform. If this is not installed prior to running the Raptor installation program, it will be downloaded (internet access required) during the installation process.
** Raptor requires the Microsoft .NET framework that comes preinstalled on most current versions of the Windows platform. If this is not installed prior to running the Raptor installation program, it will be downloaded (internet access required) during the installation process.
** If necessary, the .NET framework can be downloaded manually at: [http://www.microsoft.com/en-us/download/details.aspx?id=17851 www.microsoft.com]
** If necessary, the .NET framework can be downloaded manually at: '''[http://www.microsoft.com/en-us/download/details.aspx?id=17851 www.microsoft.com]'''.
 
 
=====MATLAB Version support=====
Raptor currently requires Windows 7 (32 or 64 bit versions) and MATLAB 2012a+


=====MATLAB Version Support=====
Raptor currently requires Windows 7 or Windows 10 and MATLAB 2015b or newer.
For the most recent compatibility information, please visit our wiki site at: '''[[Raptor:Versions|Raptor Versions]]'''.
[[File:Raptor Compatibility Matrix.PNG|Raptor Compatibility]]
[[File:Raptor Compatibility Matrix.PNG|Raptor Compatibility]]


=====Installation=====
=====Installation=====
# Download and run the latest Raptor installer program
# Download and run the latest Raptor installer program.
## Follow the instructions and change the options to your liking
## Follow the Raptor-Dev User Manual instructions.
# When the installer finishes, run the '[[Raptor:Tools|Raptor Configuration Editor]]'
# When the installer finishes, run the '''[[Raptor:Tools|Raptor Configuration Editor]]'''.
## This shows which versions of MATLAB and Raptor are compatible
## This shows which versions of MATLAB and Raptor are compatible.
## Set the configuration settings for your version of MATLAB
## Set the configuration settings for your version of MATLAB.
# Verify your Raptor License
## For advanced users, the RAPTOR_DIR and custom path options allow for additional configuration options.
## Open the Start menu and go to "New Eagle -> [[Raptor:Tools|New Eagle License Viewer]]"
# Verify your Raptor License.
## From the MATLAB command prompt, type >>raptor_check_license
## If you have a dongle license, insert your USB license dongle into a USB port on your computer.
# Verify MATLAB/Simulink Integration
## Open the Start menu and go to '''New Eagle''' -> '''[[Raptor:Tools|New Eagle License Viewer]]'''.
## In the MATLAB command prompt, type '''>>raptor_check_license'''
# Verify MATLAB/Simulink integration.
## When Raptor has been properly integrated, you will see the following message upon starting MATLAB:
## When Raptor has been properly integrated, you will see the following message upon starting MATLAB:
:: [[file:RaptorInitialized.jpg|frame|center]]
:: [[file:RaptorInitialized.jpg|left]]
<br/>
<br/>
<br/>


== Software/Code-Generation ==
== Software/Code-Generation ==
=====Creating a Sample Raptor Project=====
=====Creating a Sample Raptor Project=====
The easiest way to create a new Raptor project is to use the 'raptor_create_project' script from the command prompt. This script will create a new project with the appropriate code-generation settings for Raptor. The new project will have a few useful folders where you may want to store project files in the future (CAN, Images, Libraries). These folders are automatically added/removed from the path when the model is opened/closed via the model_open/model_close scripts that are generated alongside the model (mdl) file.
The easiest way to create a new Raptor project is to use the 'raptor_create_project' function in the command prompt. This script will create a new project with the appropriate code-generation settings for Raptor. The new project will have a few useful folders where you may want to store project files in the future (CAN, Images, Libraries). These folders are automatically added/removed to the path when the model is opened/closed via the model_open/model_close scripts that are generated alongside the model (mdl) file.
* Open MATLAB and in the command prompt type >> raptor_create_project
* Open MATLAB and in the command prompt type '''>>raptor_create_project'''
** This will create a new project with the appropriate settings for Raptor
* This will create a new project with the appropriate settings for Raptor.
[[file:RaptorGettingStarted_CreateProject.jpg|400px]]
[[file:RaptorGettingStarted_CreateProject.jpg|400px]]
* Select the proper target with the ECU definition block
 
* Build the project by pressing 'CTRL + B' or select 'Tools->Code Generation->Build Model'
=====Test Build=====
** If successful, a message indicating so will appear in the command window
* Select the proper target with the ECU definition block, also double check to make sure the compiler you intend to use is available and selected
* Build the project by pressing 'CTRL+B' or select 'Tools -> Code Generation -> Build Model'
** If successful, a message indicating 'Successful Raptor Build' will appear in the command window
** The output files will be created and placed (by default) in C:\ECU
** The output files will be created and placed (by default) in C:\ECU
[[file:RaptorGettingStarted_OutputFiles.jpg|400px]]
[[file:RaptorGettingStarted_OutputFiles.jpg|400px]]
* You may now flash your software onto the controller using tools such as '''[http://www.neweagle.net/support/wiki/index.php?title=Raptor-Cal Raptor-Cal]'''
* You may now flash your software onto the controller using tools such as '''[[Raptor-Cal|Raptor-Cal]]'''


== Programming Setup for Raptor Modules ==
== Programming Setup for Raptor Modules ==
===== Basic Programming Procedure =====
===== Basic Programming Procedure =====


1. Install Raptor-Cal
1. Install Raptor-Cal.


During the Raptor-Cal installation, an ECU folder is created on the C: drive of the computer, with the following folders:  
During the Raptor-Cal installation, an ECU folder is created on the C: drive of the computer, with the following folders:  
:* RPG for Raptor Package (.rpg) files  
:* RPG for Raptor Package (*.rpg) files  
:* RDIS for display (.rdis) files  
:* RDIS for display (*.rdis) files  
:* RCAL for calibration (.rcal) files
:* RCAL for calibration (*.rcal) files


Please read the '''[http://www.neweagle.net/support/wiki/index.php?title=Raptor-Cal#Downloads Raptor-Cal/Raptor-Service User Guide]''' for detailed instructions on downloading and installing Raptor-Cal.
Please read the '''[[Raptor-Cal#Downloads|Raptor-Cal/Raptor-Service User Manual]]''' for detailed instructions on downloading and installing Raptor-Cal.




2. SmartCraft Hub Setup
2. SmartCraft Hub Setup


Connect the following components to the SmartCraft hub
Connect the following components to the SmartCraft hub.


:* Battery/power supply (+12V or +24V)
:* Battery/power supply (+12V or +24V)
:* Key switch
:* Key-switch
:* CAN termination resistor (120 ohms) on CAN1
:* CAN termination resistor (120Ω) on CAN1
:* Kvaser USB-to-CAN device (connect to the laptop/PC) to CAN1
:* Kvaser USB-to-CAN device (connect to the laptop/PC) to CAN1
:* ECU harness
:* ECU harness
Line 84: Line 168:


:* Make sure that battery power goes across pins A (+) and B (-)
:* Make sure that battery power goes across pins A (+) and B (-)
:* Check for continuity between pins A and F with key switch turned ON
:* Check for continuity between pins A and F with the key-switch turned ON
:* Check resistance across pins J and K (should be 120 Ohms if termination is connected)
:* Check resistance across pins J and K (should be 120Ω if termination is connected)
:* Ensure that the ECU harness has pins A, B, F, J, and K populated to account for power, ground, key switch, and CAN1.  See image below
:* Ensure that the ECU harness has pins A, B, F, J, and K populated to account for power, ground, key-switch, and CAN1.  See image below


[[File:SmartCraft_setup.jpg|300px]]
[[File:SmartCraft_setup.jpg|300px]]
Line 93: Line 177:
3. Raptor-Cal Programming Procedure
3. Raptor-Cal Programming Procedure


You will need to have a program file compiled to program. This is the .rpg file that is generated after a successful build.  The file is located in the RPG folder.
You will need to have a program file compiled to program. This is the *.rpg file that is generated after a successful build.  The file is located in the RPG folder.


:* Open Raptor-Cal
:* Open Raptor-Cal.
::[[File:RaptorCalProcedure001.png|350px]]
::[[File:RaptorCalProcedure001.png|350px]]
:* Make sure that the port setting is set to the correct baud rate and XCP settings that was last flashed/programmed onto the module. Please note that the port should be set to XCP Access Level = 4, XCP Broadcast ID (hex) = 100, and 250kbaud for a module brand new out of the package.  To check the port settings in Raptor-Cal, go to Edit -> Settings.
:* Make sure that the port setting is set to the correct baud rate and XCP settings that were last flashed/programmed onto the module. Please note that the port should be set to XCP Access Level = 4, XCP Broadcast ID (hex) = 100, and 250K baud for a module brand new out of the package.  To check the port settings in Raptor-Cal, go to Edit -> Settings.
::[[File:RaptorCalProcedure002.png|350px]]    [[File:RaptorCalProcedure003.png|350px]]
::[[File:RaptorCalProcedure002.png|350px]]    [[File:RaptorCalProcedure003.png|350px]]
:* If all of the settings and setup are correct, turn on the ECU and click "Reprogram over CAN"
:* If all of the settings and setup are correct, turn on the ECU and click "Reflash."
:* Select your module, then select the program you wish to flash onto the module
:* With a DataLink Adapter connected, Raptor-Cal will begin scanning the CAN bus for available modules. When it’s done, all modules available for reflash should be shown. Choose the desired device and either double-click or click “Select.”
::[[File:RaptorCalProcedure004.png|350px]]
::[[File:RaptorCalProcedure004.png|350px]]
:* Raptor-Cal will begin reprogramming the module
:* A dialog box will open to choose a Raptor Package (*.rpg) file in the file system. Navigate to the Raptor Package that you just created and select okay. The reflash process will begin immediately.
::[[File:RaptorCalProcedure005.PNG|350px]]
::[[File:RaptorCalProcedure005.PNG|350px]]
===== BCM48 Programming Procedure =====
Note: A Raptor license only enables reprogramming permissions in Raptor-Cal. To enable calibration and display capability in Raptor-Cal, a Raptor-Cal license is needed.
'''IMPORTANT: The model that is going to be programmed on to the BCM48 must have its CAN1 set to 250kbaud'''
 
1-2. Programming the BCM48 follows the first 2 steps of programming any other raptor module.
 
3.Configuring the Local Area Network connection
*Click on the start menu and click control panel
[[image:StartMenu.png|250px]]
*Click on network and internet.
[[image:Control_Panel.png|600px]]
*Click on change adapter settings
[[image:adapter_settings.png|600px]]
*Right click on Local Area Connection and chose properties from the drop down list
[[image:LANmenu.png|300px]]
*Select Internet Protocol Version 4 (TCP/IPv4) and click properties
[[image:LANproperties.png|300px]]
*select "Use the following IP address"
**enter 193.168.1.1 for the IP address
**the subnet mask should auto populate, if it doesn't enter 255.255.255
[[image:IP_settings.png|300px]]
 
4. Ethernet Programming Procedure
*connect the Ethernet signals from the BCM48 to the ether net adapter on your PC.
*navigate to the build folder that was used to build your raptor module.
*double click on the Flash.Bat file that was generated when the model was built.
*this should open up the command prompt and begin programming the BCM 48
*a confirmation message will be displayed when programming is complete.
*the BCM48 is now ready to communicate via CAN and can be used for display and calibration applications in Raptor-Cal.

Latest revision as of 20:09, 16 July 2024

New Eagle > Products Wiki > Raptor Platform > Raptor-Dev > Getting Started with Raptor-Dev

Downloading Raptor Software

If you have already purchased a software license, you can download the latest release of the Raptor-Dev software at software.neweagle.net.

Installation

New Eagle License Viewer
Raptor Configuration Editor
System Requirements
Component Minimum
Processor Intel compatible 2.0 GHz
RAM 4 GB (8 GB recommended)
Disk
Raptor-Dev 600 MB
Raptor-Cal 300 MB
Raptor-Service 290 MB
Raptor-CAN 10 MB
Raptor-Test 15 MB
Operating system Windows 10/8.1/7 64-bit
Additional requirements .NET Framework 4.5 - Installed with Raptor products, if not previously installed.
Prerequisites
Required: Recommended: Options:
Mathworks Software (See below) 2nd Controller CAN Data Logger
Raptor-Dev Software or Kit Boot Device/Harness Display
Control Module Crimp Tools Telematics
Compiler (See Below) Raptor-Cal Raptor-Service
Wiring, Harnesses and Connectors Training or Consulting Raptor-CAN
Break-Out Box Raptor-Test
MATLAB/Simulink Requirements
  • Raptor requires a compatible installation of MATLAB/Simulink in order to create models for code generation. The following tools from Mathworks are required:
    • MATLAB
    • Simulink
    • Embedded Coder
    • MATLAB Coder
    • Simulink Coder
    • Stateflow
Compilers
  • To compile the generated code properly for your embedded platform, the appropriate compiler and associated license will be required. For instance, Raptor targets with a Freescale 55xx Microprocessor will require the CodeWarrior 55xx compiler.
    • The CM0711 uses the CodeWarrior for MPC55xx/MPC56xx Microcontrollers V2.10 compiler. You can download an evaluation version or purchase the compiler here.
    • The GCM48, RCM80 and M47 use the S32DS for Power Architecture, Version V2.1. This is a free download from NXP; please see our S32DS Compiler Guide for installation help.
    • The GCM56, GCM111 and other Aurix based controllers use the HIGHTEC-DP-TC-NL available from the New Eagle store.
    • The RCM112, for prototype or non-FuSA applications, uses the GCC compiler included in SPC5-STUDIO. This is a free download from ST; please see SPC5-STUDIO for a link to the latest installer.
    • The RCM112, for FuSA applications, will use the HighTec PowerPC compiler available from Hitex.
    • The GCM196 and ECM196 use the Hightec Compiler for the Infineon TriCore architecture v3.4.5.11 compiler, HIGHTEC-DP-TC, purchased from the New Eagle store.
    • The GCM70 use the GCC PowerPC EABI 4.6.0 SPE compiler. This is a free download.
    • For VeeCAN targets, use the GNU Compiler Collection (GCC) which is included free as an option in the Raptor installation process.
  • .NET Framework
    • Raptor requires the Microsoft .NET framework that comes preinstalled on most current versions of the Windows platform. If this is not installed prior to running the Raptor installation program, it will be downloaded (internet access required) during the installation process.
    • If necessary, the .NET framework can be downloaded manually at: www.microsoft.com.
MATLAB Version Support

Raptor currently requires Windows 7 or Windows 10 and MATLAB 2015b or newer. For the most recent compatibility information, please visit our wiki site at: Raptor Versions. Raptor Compatibility

Installation
  1. Download and run the latest Raptor installer program.
    1. Follow the Raptor-Dev User Manual instructions.
  2. When the installer finishes, run the Raptor Configuration Editor.
    1. This shows which versions of MATLAB and Raptor are compatible.
    2. Set the configuration settings for your version of MATLAB.
    3. For advanced users, the RAPTOR_DIR and custom path options allow for additional configuration options.
  3. Verify your Raptor License.
    1. If you have a dongle license, insert your USB license dongle into a USB port on your computer.
    2. Open the Start menu and go to New Eagle -> New Eagle License Viewer.
    3. In the MATLAB command prompt, type >>raptor_check_license
  4. Verify MATLAB/Simulink integration.
    1. When Raptor has been properly integrated, you will see the following message upon starting MATLAB:




Software/Code-Generation

Creating a Sample Raptor Project

The easiest way to create a new Raptor project is to use the 'raptor_create_project' function in the command prompt. This script will create a new project with the appropriate code-generation settings for Raptor. The new project will have a few useful folders where you may want to store project files in the future (CAN, Images, Libraries). These folders are automatically added/removed to the path when the model is opened/closed via the model_open/model_close scripts that are generated alongside the model (mdl) file.

  • Open MATLAB and in the command prompt type >>raptor_create_project
  • This will create a new project with the appropriate settings for Raptor.

Test Build
  • Select the proper target with the ECU definition block, also double check to make sure the compiler you intend to use is available and selected
  • Build the project by pressing 'CTRL+B' or select 'Tools -> Code Generation -> Build Model'
    • If successful, a message indicating 'Successful Raptor Build' will appear in the command window
    • The output files will be created and placed (by default) in C:\ECU

  • You may now flash your software onto the controller using tools such as Raptor-Cal

Programming Setup for Raptor Modules

Basic Programming Procedure

1. Install Raptor-Cal.

During the Raptor-Cal installation, an ECU folder is created on the C: drive of the computer, with the following folders:

  • RPG for Raptor Package (*.rpg) files
  • RDIS for display (*.rdis) files
  • RCAL for calibration (*.rcal) files

Please read the Raptor-Cal/Raptor-Service User Manual for detailed instructions on downloading and installing Raptor-Cal.


2. SmartCraft Hub Setup

Connect the following components to the SmartCraft hub.

  • Battery/power supply (+12V or +24V)
  • Key-switch
  • CAN termination resistor (120Ω) on CAN1
  • Kvaser USB-to-CAN device (connect to the laptop/PC) to CAN1
  • ECU harness

Ensure that your setup includes the following:

  • Make sure that battery power goes across pins A (+) and B (-)
  • Check for continuity between pins A and F with the key-switch turned ON
  • Check resistance across pins J and K (should be 120Ω if termination is connected)
  • Ensure that the ECU harness has pins A, B, F, J, and K populated to account for power, ground, key-switch, and CAN1. See image below


3. Raptor-Cal Programming Procedure

You will need to have a program file compiled to program. This is the *.rpg file that is generated after a successful build. The file is located in the RPG folder.

  • Open Raptor-Cal.
  • Make sure that the port setting is set to the correct baud rate and XCP settings that were last flashed/programmed onto the module. Please note that the port should be set to XCP Access Level = 4, XCP Broadcast ID (hex) = 100, and 250K baud for a module brand new out of the package. To check the port settings in Raptor-Cal, go to Edit -> Settings.
  • If all of the settings and setup are correct, turn on the ECU and click "Reflash."
  • With a DataLink Adapter connected, Raptor-Cal will begin scanning the CAN bus for available modules. When it’s done, all modules available for reflash should be shown. Choose the desired device and either double-click or click “Select.”
  • A dialog box will open to choose a Raptor Package (*.rpg) file in the file system. Navigate to the Raptor Package that you just created and select okay. The reflash process will begin immediately.

Note: A Raptor license only enables reprogramming permissions in Raptor-Cal. To enable calibration and display capability in Raptor-Cal, a Raptor-Cal license is needed.