=== CAN ===
=== CAN ===
MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk block set).  The CAN IDs are also not configurable.
MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk blockset).  The CAN IDs are also not configurable.


=== Input Specification ===
=== Input Specification ===


*Max Voltage is +18 volts. Above 18 volts, the unit might become damaged.  
*Max voltage is +18 volts. Above 18 volts, the unit might become damaged.  
*The interface circuits and the electronic device connected to the network are designed to withstand overvoltage and wiring errors.  
*The interface circuits and the electronic device connected to the network are designed to withstand overvoltage and wiring errors.  
*No permanent damage will result from a voltage level of +/- 18 volts applied between any two wires in the interface over an indefinite period of time.
**No permanent damage will result from a voltage level of +/- 18 volts applied between any two wires in the interface over an indefinite period of time.
*No permanent damage will result from miswiring the interface lines in any combination over an indefinite period of time.
**No permanent damage will result from miswiring the interface lines in any combination over an indefinite period of time.


=== CAN Specification ===
=== CAN Specification ===
Line 109: Line 109:


===Datasheet Errata===
===Datasheet Errata===
The operating temperature is -40°C to +85°C. (Datasheet incorrect as of February 23, 2023.)
The operating temperature is -40°C to +85°C. (Datasheet is incorrect as of February 23, 2023.)


==Webstore==
==Webstore==


This product has been discontinued.
This product has been discontinued.

Latest revision as of 18:43, 24 February 2023

Displays

Overview

Note: This gauge should not be used for development projects due to the end of its production. Please visit the MiniView 1700 page for new projects incorporating this gauge.

This rugged display unit is capable of operating in harsh marine and off-highway applications. Designed to operate with the MotoHawk line of rugged controllers, the circular display (65 pixels high, 65 pixels wide, 4 built-in fonts, adjustable backlight) is controlled from the customer application via the MiniView CAN interface, typically using the MotoHawk blockset. If you're looking for a more functional, color display that is just as affordable as the MiniView, you may want to check out the VeeCAN 320.


For product downloads such as datasheets, drawings or user manuals, please return to the previous page here.


Features include:

  • Operating temperature: -40°C to +85°C
  • CANbus data link
  • Comes with SmartCraft connector
  • IP-X7 Marine Protection Rating
  • Rugged case

Application Note

CAN

MiniView comes with a fixed CAN baud rate of 250kbps (not configurable via the MotoHawk blockset). The CAN IDs are also not configurable.

Input Specification

  • Max voltage is +18 volts. Above 18 volts, the unit might become damaged.
  • The interface circuits and the electronic device connected to the network are designed to withstand overvoltage and wiring errors.
    • No permanent damage will result from a voltage level of +/- 18 volts applied between any two wires in the interface over an indefinite period of time.
    • No permanent damage will result from miswiring the interface lines in any combination over an indefinite period of time.

CAN Specification

Message ID Purpose D0 D1 D2 D3 D4 D5 D6 D7
0x421 Heartbeat Hardware Type Software Version
0x422 Set Backlight percent
0x423 Draw Line x0 y0 x1 y1 attrib msb attrib lsb color fill color
0x424 String Xfer page, string* char 0 char 1 char 2 char 3 char 4 char 5 char 6
0x424 String Xfer page, string* char 7 char 8 char 9 char 10 char 11 char 12 char 13
0x424 String Xfer page, string* char 14 char 15 char 16 char 17
0x425 Draw String String # x loc y loc font attrib msb attrib lsb color fill color
0x426 Clear Screen
0x427 Draw Rect x0 x1 y0 y1 attrib msb attrib lsb color fill color
0x428 Draw H Line x0 x1 y attrib msb attrib lsb color fill color
0x429 Draw V line x y0 y1 attrib msb attrib lsb color fill color
0x42A Set GUI Mode mode
0x42B Draw Bitmap bitmap x loc y loc attrib msb attrib lsb color fill color
0x42F Button Pressed button asserted count

Libraries

The MiniView Library is a useful tool that allows users to program a custom display using MotoHawk blocks. For more information, refer to the MiniView Library Datasheet.

Downloads

Datasheet
Libraries
Library Datasheet
Bar Graph

Datasheet Errata

The operating temperature is -40°C to +85°C. (Datasheet is incorrect as of February 23, 2023.)