Raptor™ OBD Counter Definition

Description

This block defines an OBD counter. It is a 16 bit counter which will increment from 0 to 65535 and then rollover to 0. The counter can only be incremented once per drive cycle regardless of the number of times the increment block is executed. The OBD counter can be used to implement the general denominator and ignition cycle counter. This block requires the OBD Fault Manager to be included in the model.

Parameters

Parameter Type Description
Counter Name The name of the counter. This must be unique.
Visible in Cal Tool Controls the visibility of the counter data in the calibration tool.
Unit Text Strings Sets the unit text that is displayed in the calibration tool.
Help Text Strings Sets the help text that is displayed in the calibration tool.
Access Level Sets the access level of this item in the calibration tool
Function String Sets the location where the variable appears in the calibration tool. Use raptor_xcp_function(gcb) to create a function based on this block's location in the model.